5-23
16. Strobe Adjustment
Adjust the light level and white balance when the strobe light flashes.
Mode
Still (Auto (
))
Subject
Paper which reflection rate is 18%
(Note2) (1.0m from the front of the lens)
Measurement Point
Data of page F, address: 64 and
Display data of page 1
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
4D, 4E, 64, 69 to 6B
Specified Value1
60 to 94
Specified Value2
FA to FF or 00 to 06
Specified Value3
FA to FF or 00 to 06
Note1:
This adjustment should be carried out upon completion of “Data
Setting during Camera System Adjustments”.
Note2:
Background paper (J-250-130-A). Perform this adjustment in the
dark room or use a dark box.
Note3:
Any light other than the strobe light should not light up the plate.
Note4:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note5:
Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Lower data
Upper data
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
2
04
10
Set the data, and press PAUSE
button.
3
Check that the flash is popped up.
4
6
90
00
Set the data.
5
6
91
00
Set the data.
6
6
92
FF
Set the data.
7
6
93
FF
Set the data.
8
6
6C
01
Set the data.
9
6
2C
01
Set the data.
10
6
01
79
Set the data, and press PAUSE
button.
11
6
07
Check that the data changes to “01”.
12
6
01
67
Set the data, and press PAUSE
button.
13
6
02
Check the flashing, and check
that the data changes to “01”.
14
6
01
00
Set the data, and press PAUSE
button.
15
6
01
67
Set the data, and press PAUSE
button.
16
6
02
Check the flashing, and check
that the data changes to “01”.
17
6
01
00
Set the data, and press PAUSE
button.
18
6
01
B9
Set the data, and press PAUSE
button.
19
6
02
Check the flashing, and check that
the data changes to “01”. (Note6)
20
6
01
00
Set the data, and press PAUSE
button.
21
6
01
67
Set the data, and press PAUSE
button.
22
6
02
Check that the data changes to
“01”. (Note6)
23
F
64
Check that the display data
satisfies the specified value1.
24
0
03
02
Set the data.
25
1
Check that the upper data of display
data satisfies the specified value2.
26
1
Check that the lower data of display
data satisfies the specified value3.
27
2
04
00
Set the data.
Note6:
The adjustment data will be automatically input to page: F, address:
4D, 4E, 64, 69 to 6B.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
2C
00
Set the data.
3
6
6C
00
Set the data.
4
6
92
00
Set the data.
5
6
93
00
Set the data.
6
0
01
00
Set the data.
7
0
03
00
Set the data.
RadarW
RadarW
RadarW
Содержание MVC-CD200
Страница 67: ...MVC CD200 CD300 4 65 RGB DRIVE TIMING GENERATOR BACK LIGHT PK 58 EXPOSURE SPOT METER ...