5-14
3. Flange Back Adjustment
3-1. Flange Back Adjustment (1)
(Using Flange Back Adjustment Chart)
The inner focus lens flange back adjustment is carried out
automatically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
Mode
Still (Auto (
))
Subject
Flange back adjustment chart
(2.0 m from the front of the protection
glass) (Luminance: 350 ± 50 lux)
Measurement Point
Display data of page: F, address: 87
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
14 to 25, 87, 8A , 8B (MVC-CD200)
14 to 25, 87 to 9B (MVC-CD300)
Specified value
00
Note1:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
13
Set the data, and press PAUSE
button.
3
6
01
15
Set the data, and press PAUSE
button.
4
6
02
Check that the data changes to
“01”. (Note2)
5
F
87
Check that the data is “00”.
Note2:
The adjustment data will be automatically input to the adjustment
addresses.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
0
01
00
Set the data.
3
Perform “Flange Back Adjustment
(2)”. (MVC-CD200)
Perform “Flange Back Check”.
(MVC-CD300)
3-2. Flange Back Adjustment (2)
(MVC-CD200)
Perform this adjustment after performing “Flange Back Adjustment
(1)”.
Mode
Still (Auto (
))
Subject
Subject more than 500m away
(Subjects with clear contrast such as
buildings, etc.)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Adjustment Page
F
Adjustment Address
14 to 25, 87, 8A , 8B
Note1:
Make the lens horizontal and perform this adjustment.
Preparations:
1)
Set the zoom lens to the TELE end and expose a subject that is
more than 500m away (subject with clear contrast such as
building, etc.). (Nearby subjects less than 500m away should
not be in the screen.)
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
13
Set the data, and press PAUSE
button. (Note2)
Place a ND filter on the lens so that
the optimum image is obtained.
3
6
01
29
Set the data, and press PAUSE
button.
4
6
02
Check that the data changes to
“01”. (Note2)
Note2:
The adjustment data will be automatically input to the adjustment
addresses.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
Perform “Flange Back Check”.