5-20
12. Color Reproduction Adjustment
Adjust the color Separation matrix coefficient so that proper color
reproduction is produced.
12-1. Color Reproduction Adjustment
Mode
Still (Auto (
))
Subject
Color bar chart
(Color bar standard picture frame)
Adjustment Page
F
Adjustment Address
41 to 48, 5C to 5F
Note1:
This adjustment should be carried out upon completion of “Data
Setting during Camera System Adjustments”.
Note2:
After the power is turned on, this adjustment can be done only once.
Note3:
Check that the data of page: 6, address: 02 is “00”. If not, turn off
the power and turn on again.
Note4:
This adjustment must be performed in NTSC mode.
Switch setting:
ZOOM .................................................................... WIDE end
FOCUS ............................................................ Manual (0.3m)
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
B
75
Check that the data is “00”.
(Note1)
3
6
12
80
Set the data, and wait for 1 sec.
4
6
12
00
Set the data, and wait for 2 sec.
5
6
01
A9
Set the data, and press PAUSE
button.
6
6
02
Check that the data changes to
“01”. (Note5)
Note5:
The adjustment data will be automatically input to page: F, address:
41 to 48, 5C to 5F.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
0
01
00
Set the data.
12-2. Color Reproduction Check
Mode
Still (Auto (
))
Subject
Color bar chart
(Color bar standard picture frame)
Measurement Point
Video output terminal
Measuring Instrument
NTSC vectorscope
Specified Value
Each center of all color luminance
points should settle within each color
reproduction frame.
Note1:
This adjustment should be carried out upon completion of “Data
Setting during Camera System Adjustments”.
Note2:
This adjustment must be performed in NTSC mode.
Note3:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
ZOOM .................................................................... WIDE end
FOCUS ............................................................ Manual (0.3m)
Checking method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
B
75
Check that the data is “00”.
(Note1)
3
4
06
01
Set the data.
4
6
10
01
Set the data.
5
E
52
Write down the data.
6
E
52
09
Set the data, and press PAUSE
button.
7
6
01
0F
Set the data, and press PAUSE
button.
8
6
12
80
Set the data, and wait for 1 sec.
9
6
12
00
Set the data, and wait for 2 sec.
10
Adjust the GAIN and PHASE of
the vectorscope so that the burst
luminance point is set at the
specified position.
11
Check that each center of all color
luminance points is set in each
color reproduction frame.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
10
00
Set the data.
3
4
06
00
Set the data.
4
E
52
Set the data that is written down
at step 5, and press PAUSE button.
5
0
01
00
Set the data.
Burst position
Fig. 5-1-13.
RadarW
RadarW
RadarW
RadarW
RadarW
Содержание MVC-CD200
Страница 67: ...MVC CD200 CD300 4 65 RGB DRIVE TIMING GENERATOR BACK LIGHT PK 58 EXPOSURE SPOT METER ...
Страница 131: ...Sony EMCS Co Kohda TEC MVC CD200 CD300 162 9 929 900 31 2001E1600 1 2001 5 Published by PV Customer Center ...
Страница 132: ...Revision History Ver 1 0 Date 2001 05 History Official Release Contents S M Rev issued 992990031 pdf Reverse ...