6-1 Overview of Editing Functions
Chapter 7 Setup Menu
7-10
Chapter 7
Setup Menu
When you control the MDS-B5 with the remote
controller or the keyboard or use the deck as a sub or
end deck during direct ATRAC data copying, you can
disable the buttons on the front panel of the MDS-B5
to avoid unintentional touch of the operation buttons
(Kill Local function). You can choose from two
setting modes (“Kill Almost” and “Kill All”).
For the connection when you use the direct ATRAC data
copy function, see “3-2-3 Connection for Direct ATRAC
Data Copying” on page 3-3.
Disabling the buttons on the front panel
1
Press the EDIT/NO button while holding down the
STOP button.
The Setup menu appears.
2
Turn the AMS control until the menu item F26
(“Kill Almost” or “Kill All”) appears.
3
Press the AMS control.
The indication flashes to show that you can change
the setting.
7-10 Disabling the Buttons While Controlling Remotely
4
Turn the AMS control to select the mode from the
values below.
Kill Almost: Only the STOP, EJECT, and
DISPLAY buttons are in effect.
Kill All: All the buttons on the front panel are
disabled.
5
Press the AMS control to affect the setting and exit
from the Setup menu.
1
2 – 5
p
(P
0
)
=
+
r
K i l l A l m o s t
F26