2-11
IXS-6600/6700
2-4. Data Backup
The table data that are set from the personal computer (to be abbreviated as PC hereafter) are stored in the
RAM on the CA-65 board. Backing up the stored data is recommended in the case of emergency such as
data are damaged or lost.
Backing up the stored data is performed using the software BZR-20 supplied with the IXS-6700/IXS-
6600.
2-4-1. Connection
Connect the equipment as shown below for uploading and downloading the stored data.
Method of connecting each BZR-20 that is shown in the illustration, and the stored data that can be
uploaded and/or downloaded are described below.
BZR-20
Connection
Connection method
Setup data that can be
uploaded/downloaded
BZR-20-
1
REMOTE3 connector
RS-232C crossover cable
The various setup data of the primary
of the IXS-6700/IXS-6600
(
9
-pin to
9
-pin)
station (IXS-6700/IXS-6600),
and a PC
the Routing Switchers 1 to 2,
the Remote Control Panels 1 to 4,
and the BZR-IF810-
1
to
2
BZR-20-
2
Primary station (BZR-IF810-
1
)
RS-232C crossover cable
The various setup data of the Remote
and a PC
(
9
-pin to
9
-pin)
Control Panels 5 to 8, and the BZR-
IF810-
1
BZR-20-
3
Primary station (BZR-IF810-
2
)
RS-232C crossover cable
The various setup data of the Remote
and a PC
(
9
-pin to
9
-pin)
Control Panels
9
to 12, and the BZR-
IF810-
2
BZR-20-
4
NETWORK connector of the
Ethernet
The various setup data of the primary
primary (IXS-6700/IXS-6600 )
station (IXS-6700/IXS-6600),
station and a PC
the Routing Switchers 1 to 2,
the Remote Control Panels 1 to 4,
and the BZR-IF810-
1
to
2
NETWORK
BZR-IF810-
1
RS-232C
RS-232C
RS-232C
BZR-IF810-
2
Remote Control Panels
Remote Control Panels
1-4
5-8
Remote Control Panels
9
-12
S-BUS
IXS-6700/IXS-6600
(Primary Station)
Routing Switcher 1-2
NETWORK
BZR-20-
1
BZR-20-
2
BZR-20-
3
BZR-20-
4
Ethernet
Содержание ixs-6600