2-6
IXS-6600/6700
a) A2 or B2 is not displayed on the IXS-6600. Power unit A and B of the IXS-
6600 are displayed as A1 and B1 in the display window respectively.
b) The displayed slot number corresponds to the input or output slot number
on the rear panel of the IXS-6600/6700 as shown below.
FAN ERR
x UNIT FAIL
L/R
.
.
One or more fan units stop or
rotation speed exceeds the
defined value.
.
Replace any defective fan units.
x RUN HOURS
OVER
L/R
.
The elapsed time of the fan unit
is past the defined time for
periodic replacement.
.
Replace the fan unit indicated by
OVER.
TEMP ERR
HIGH
_
Internal temperature exceeds the
defined value.
.
Check the ambient temperature
and the ventilation condition of the
unit .
XPT ERR
INxxx-OUTxxx
Input and output
connector
number
.
There is a problem with the
crosspoint.
.
Replace a defective optional board.
OPTION
S-BUS CPU
ERR
BD.ERR
FRONT SLOTxx 1/2/3/4/5/6/7/8
.
There is a problem with the
optional front board inserted in
the unit.
.
Replace a defective optional board.
.
The slot where the board is
inserted is not correct.
.
Insert the board in the correct slot.
REAR SLO
MAINx FAIL
Txx
1/2/3/4/5/6/7/8
A/B/C
BACKUPx FAIL A/B/C
/
9/10/11/12/13/
14/15/16
b)
.
There is a problem with the
optional rear board inserted in
the unit.
.
Replace a defective optional board.
.
T
.
There is a problem with S-BUS
CPUx on the CPU board on the
Main
side.
.
Replace a defective IF-844 board
(on the CA-65 board on the Main
side).
.
There is a problem with S-BUS
CPUx on the CPU board on the
Backup
side.
.
Replace a defective IF-844 board
(on the CA-65 board on the
Backup
side).
he slot where the board is
inserted is not correct.
.
Insert the board in the correct slot.
Display on the
1st line
Display on the
2nd line
Word in “x”
Meaning
Countermeasures
Slot number
IXS-6700
IXS-6600
SLOT1
OUT1
OUT1
SLOT2
OUT2
OUT2
SLOT3
IN1
IN1
SLOT4
IN2
IN2
SLOT5
OUT3
OUT3
SLOT6
OUT4
OUT4
SLOT7
IN3
IN3
SLOT8
IN4
IN4
SLOT9
OUT5
_
SLOT10
OUT6
_
SLOT11
IN5
_
SLOT12
IN6
_
SLOT13
OUT7
_
SLOT14
OUT8
_
SLOT15
IN7
_
8
_
SLOT16
IN
c) The WORD SYNC IN terminal of the IXS-6600 is a single system,