1-36
IXS-6600/6700
3. DVP-39 Board <IKS-V6050M/SD>
D1240
D1201
D1202
D1203
D1231 D1232 D1233 D1234 D1235 D1236 D1237 D1238 D1239
D3
D1
D8
D1206 D1207 D1208 D1209 D1210 D1211 D1212 D1213
D1214 D1215 D1216 D1217 D1218 D1219 D1220 D1221 D1222
D1223 D1224 D1225 D1226 D1227 D1228 D1229 D1230
AB
1
2
3
4
5
6
7
8
9
10
11
12
13
S1001
S1002
S1201
<LED>
D1 (A-3) :
+
+
+
+
+
12 V_CTRL
Status indication of the
+
12 V power supply on the
Control CPU.
Lights when the
+
12 V power on the control CPU is
supplied.
If this LED does not turn on, the fuse may have blown.
D3 (A-3) :
+
+
+
+
+
12 V_MAIN
Status indication of
+
12 V power supply on the main CPU.
Lights when the
+
12 V power on the main CPU is sup-
plied.
If this LED does not light, the fuse may have blown or the
board is broken.
D8 (A-4) :
+
+
+
+
+
3.3 V
+
3.3 V power supply status indication
Lights when the
+
3.3 V power is supplied.
When the
+
12 V power supply is not supplied either to the
main or control CPU, this LED does not light.
D1201 (A-10) : EPR2_MAIN
Used for production.
Lights with the factory default settings.
D1202 (A-10) : EPR2_CNO1
Used for production.
Turns off with the factory default settings.
D1203 (A-10) : EPR2_CNO2
Used for production.
Turns off with the factory default settings.
D1206 to D1239 (A-4 to A-8) : LOCK
Lights when the relocker is locked to the signal of each
channel between 1 and 34.
Turns off when LOCK is disabled.
<Switch>
S1001 (A-11) : DIP SW
Used for production.
Default setting when shipped from the factory is all OFF.
S1002 (A-12) : DIP SW
Used for production.
Default setting when shipped from the factory is all OFF.
S1201 (A-10) : EPR2_SEL
Used for production.
Default setting when shipped from the factory is “0”.