1-2
IXS-6600/6700
1-2. Operating Environment
Operating guaranteed temperature :
+
5
d
C to
+
40
d
C
Performance guaranteed temperature :
+
10
d
C to
+
35
d
C
Operating humidity :
10 % to 90 %
(relative humidity)
Storage temperature :
_
20
d
C to
+
60
d
C
Mass (when all options are installed) :
IXS-6700 :
Approx. 41 kg
IXS-6600 :
Approx. 24 kg
Prohibited locations for installation
.
Areas where the unit will be exposed do direct sunlight
or any other strong lights.
.
Dusty areas
.
Areas subject to vibration.
.
Areas with strong electric or magnetic fields.
.
Areas near heat sources.
.
Areas subject to electrical noise.
.
Areas subject where is subjected to static electricity.
Ventilation
The inside of the IXS-6700-C/IXS-6600-C (IXS-6000
series hereafter) is cooled by a fan (both sides).
The power supply can be damaged if the exhaust vent
(both sides) and air intake (front panel) are blocked or the
fan is stopped.
Therefore, leave a blank space of more than 10 cm in the
front and both sides of the IXS-6000 series.
1-3. Power Supply
1-3-1. Power Specifications
A switching regulator is used for the power supply of this
unit. The voltage within the range of 100 V to 240 V can
be used without changing the supply voltage.
Power requirements :
AC 100 to 240 V
Power frequency :
50/60 Hz
Current consumption (at the time of full options installa-
tion) :
IXS-6700 : 9.8 to 4.5 A
IXS-6600 : 6 to 2.5 A
m
.
As the inrush current at turn-on is a maximum of 145 A
(at 100 V)/110 A (at 240 V) with the IXS-6700, or a
maximum of 100 A (at 100 V)/100 A (at 240 V) with the
IXS-6600, the capacity of the AC power source must be
commensurate with this load.
If the capacity of the AC power is not adequately large,
the AC power source breaker will operate or the unit will
abnormally operate.
.
The IXS-6700 contains the four power supply units as
the standard configuration.
The units A1 and B1, and the units A2 and B2 perform
the backup operation for the two main power supply
systems respectively totaling four power supply systems.
Therefore, turn ON the power of all four units when
starting up the system.
.
The IXS-6600 contains the two power supply units as
the standard configuration.
The units A and B perform the backup operation for the two
main power supply systems respectively. Therefore, turn
ON the power of all two units when starting up the system.
1-3-2. Recommended Power Cord
w
.
Use the approved Power Cord (3-core mains lead)/Appli-
ance Connector/Plug with earthing-contacts that conforms
to the safety regulations of each country if applicable.
.
Use the Power Cord (3-core mains lead)/Appliance
Connector/Plug conforming to the proper ratings (Volt-
age, Ampere).
If you have questions on the use of the above Power Cord/
Appliance Connector/Plug, please contact your local Sony
Sales Office/Service Center.
c
.
Never use an injured power cord.
.
Plugging the power cord in the AC inlet, push as far as it
will go.
For customers in the U.S.A. and Canada
1
Power cord, 125 V 10 A, 2.4 m (8 ft) :
!
1-557-377-11
AC inlet
1
For customers in the all European countries
1
Power cord, 250 V 10 A, 2.4 m (8 ft) :
!
1-782-929-22
1
AC inlet