![Sony ixs-6600 Скачать руководство пользователя страница 31](http://html.mh-extra.com/html/sony/ixs-6600/ixs-6600_installation-manual_400393031.webp)
1-23
IXS-6600/6700
1-9. System Connection
1-9-1. S-BUS Data Link
The routing switcher system is connected with the S-BUS data link using a 75
Z
coaxial cable.
The main equipment of the S-BUS data link is shown in the table below.
Type in S-BUS
Model (function name)
Quantity
Function/role
data link
Primary station (P)
*
Routing switcher controller
1
Controls the entire S-BUS data
HKSP-R80
link.
Routing switcher
Can also function as a secondary
IXS-6700/IXS-6600
station.
(integrated routing switcher)
HDS-X5800
(routing switcher processor)
Secondary station (S)
*
Remote control unit
253 (max.)
Controls the individual secondary
BKS-R3220
station.
(X-Y control unit)
Operates in accordance with
BKS-R3219
the commands from the primary
(32 button control unit)
station.
BKS-R1617
(universal control unit)
BKS-R1618
(16 button control unit)
BKS-R3216
(8 destination control unit)
Terminal
Personal computer
1
Establishes the various setups of
(terminal emulator)
the system.
The errors that have occurred in
the S-BUS line are displayed and
managed by the emulator.
*
: (P) and (S) indicate the setting of the S/P selector switch on the CPU board (on the CA board for the IXS series) in the routing
switcher.
n
Switchers other than the IXS-6700/IXS-6600 can be also set as a primary station. In this case, some
functions are limited.