
6-132
HVR-Z7J/Z7U/Z7N/Z7E/Z7P/Z7C
2.
COMPONENT OUT Y Level Adjustment
(TT-007 board)
Mode
CAMERA mode
Subject
Arbitrary
Measurement Point
Y signal terminal of COMPONENT
OUT jack (75
Ω
terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
8C
Specified value
Y level: A = 1000
±
10 mVp-p
Sync level: B = C = 300
±
10 mVp-p
Switch setting:
1) REC FORMAT (Menu setting) ............................. HDV1080i
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
3
71
01
Press PAUSE (Write) button.
3
0
10
01
4
8
5C
Set the bit value of bit0 is
(18)
“1”, and press PAUSE
(Write) button. (Note)
5
8
5D
05
Press PAUSE (Write) button.
(18)
6
0
10
00
7
C
8C
Change the data and set the
Y signal level (A) to the
specified value.
8
C
8C
Press PAUSE (Write) button.
9
Check the sync signal (B, C)
to the specified value.
10
0
10
01
11
8
5C
Set the bit value of bit0 is
(18)
“0”, and press PAUSE
(Write) button. (Note)
12
8
5D
00
Press PAUSE (Write) button.
(18)
13
0
10
00
14
3
70
10
Press PAUSE (Write) button.
15
3
70
Check the data changes to
“11”.
16
0
01
00
Note:
For the bit values, refer to “6-4. SERVICE MODE”, “4-4.
3. Bit value discrimination”.
H
A
C
B
Fig. 6-3-6
3.
COMPONENT OUT Pr Level Adjustment
(TT-007 board)
Mode
CAMERA mode
Subject
Arbitrary
Measurement Point
Pr signal terminal of COMPONENT
OUT jack (75
Ω
terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
8E
Specified value
Pr level: A = 525
±
10 mVp-p
Sync level: B = C = 300
±
10 mVp-p
Switch setting:
1) REC FORMAT (Menu setting) ............................. HDV1080i
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
3
71
01
Press PAUSE (Write) button.
3
0
10
01
4
8
5C
Set the bit value of bit0 is
(18)
“1”, and press PAUSE
(Write) button. (Note)
5
8
5D
05
Press PAUSE (Write) button.
(18)
6
0
10
00
7
C
8E
Change the data and set the
Pr signal level (A) to the
specified value.
8
C
8E
Press PAUSE (Write) button.
9
Check the sync signal (B, C)
to the specified value.
10
0
10
01
11
8
5C
Set the bit value of bit0 is
(18)
“0”, and press PAUSE
(Write) button. (Note)
12
8
5D
00
Press PAUSE (Write) button.
(18)
13
0
10
00
14
3
70
10
Press PAUSE (Write) button.
15
3
70
Check the data changes to
“11”.
16
0
01
00
Note:
For the bit values, refer to “6-4. SERVICE MODE”, “ 4 - 4 .
3. Bit value discrimination”.
H
A
C
B
Fig. 6-3-7
Содержание HDV HVR-Z7E
Страница 496: ...144 Index Continued Zoom ring 27 ZOOM switch 27 ZOOM TRANS 46 ...
Страница 497: ......
Страница 498: ......