6-41
HVR-Z7J/Z7U/Z7N/Z7E/Z7P/Z7C
8.
Linear Matrix Adjustment
RadarW
RadarW
RadarW
Adjust the matrix coefficient for compensating the variation in
spectral sensitivity.
Adjustment Page
6D
Adjustment Address
B0 to F7
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 10, and set data: 06.
3) Input the following data to page: D (6D), address: B0 to F7.
Note:
Press the PAUSE (Write) button of the adjustment remote com-
mander each time to set data.
Address
Data
Address
Data
B0
04
D4
04
B1
00
D5
19
B2
00
D6
FF
B3
00
D7
AF
B4
00
D8
00
B5
00
D9
0A
B6
00
DA
FF
B7
00
DB
B6
B8
04
DC
04
B9
00
DD
70
BA
00
DE
FF
BB
00
DF
8F
BC
00
E0
00
BD
00
E1
00
BE
00
E2
FF
BF
00
E3
EC
C0
04
E4
04
C1
00
E5
2C
C2
04
E6
04
C3
00
E7
D5
C4
00
E8
FF
C5
00
E9
74
C6
00
EA
FF
C7
00
EB
E1
C8
00
EC
FF
C9
00
ED
80
CA
04
EE
04
CB
00
EF
F3
CC
00
F0
FE
CD
00
F1
EC
CE
00
F2
FF
CF
00
F3
F8
D0
00
F4
FF
D1
00
F5
D5
D2
04
F6
05
D3
00
F7
35
4) Select page: 0, address: 10, and set data: 00.
5) Select page: 0, address: 01, and set data: 00.
7.
Black Balance
RadarW
RadarW
RadarW
Adjust the black level.
Subject
Not required
Measurement Point
Measuring Instrument
Adjusting remote commander
Adjustment Page
6E
Adjustment Address
C6 to EF
Note 1:
If reading/writing data on pages 6E, set data: 06 to
page: 0, address: 10, and then select pages E. By this
data setting, the pages 6E can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Check that the data of page: 6, address: 02 is “00”
If not, select page: 6, address: 01, set data: 00, and press
the PAUSE (Write) button.
Switch setting
1) POWER ......................................................... CAMERA mode
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
07
Check the data is “04”.
3
0
10
01
4
6
07
Check the data is “04”.
(16)
5
0
10
00
6
6
01
BF
Press PAUSE (Write) button.
(Note 3)
7
6
02
Check the data changes to
“01”.
Note 3:
The adjustment data will be automatically input to page:
6E, address: C6 to EF.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
0
01
00
Содержание HDV HVR-Z7E