6-121
HVR-A1J/A1U/A1N/A1E/A1P/A1C
5.
COMPONENT OUT Pr Level Adjustment
(TT-001 board)
Mode
CAMERA-TAPE
Subject
Arbitrary
Measurement Point
Pr signal terminal of COMPONENT
OUT jack (75
Ω
terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
83
Specified value
Pr level: A = 525
±
10 mVp-p
Sync level: B = C = 300
±
10 mVp-p
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Switch setting:
1) REC FORMAT (Menu setting) ............................. HDV1080i
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
01
3
8
01
Set the bit value of bit2 is
“1”, and press PAUSE
(18)
(Write) button.
4
0
10
00
5
C
83
Change the data and set the
Pr signal level (A) to the
specified value.
6
C
83
Press PAUSE (Write) button.
7
Check the sync signal (B, C)
to the specified value.
8
0
10
01
9
8
01
Set the bit value of bit2 is
“0”, and press PAUSE
(18)
(Write) button.
10
0
10
00
11
0
01
00
Note 2:
For the bit values, refer to “6-4. SERVICE MODE”,
“4-4. 3. Bit value discrimination”.
H
A
C
B
Fig. 6-3-7
6.
COMPONENT OUT Pb Level Adjustment
(TT-001 board)
Mode
CAMERA-TAPE
Subject
Arbitrary
Measurement Point
Pb signal terminal of COMPONENT
OUT jack (75
Ω
terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
84
Specified value
Pb level: A = 525
±
10 mVp-p
Sync level: B = C = 300
±
10 mVp-p
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Switch setting:
1) REC FORMAT (Menu setting) ............................. HDV1080i
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
01
3
8
01
Set the bit value of bit2 is
“1”, and press PAUSE
(18)
(Write) button.
4
0
10
00
5
C
84
Change the data and set the
Pb signal level (A) to the
specified value.
6
C
84
Press PAUSE (Write) button.
7
Check the sync signal (B, C)
to the specified value.
8
0
10
01
9
8
01
Set the bit value of bit2 is
“0”, and press PAUSE
(18)
(Write) sbutton.
10
0
10
00
11
0
01
00
Note 2:
For the bit values, refer to “6-4. SERVICE MODE”,
“4-4. 3. Bit value discrimination”.