![Sony HDV HVR-A1U Скачать руководство пользователя страница 216](http://html.mh-extra.com/html/sony/hdv-hvr-a1u/hdv-hvr-a1u_service-manual_1323564216.webp)
6-57
HVR-A1J/A1U/A1N/A1E/A1P/A1C
29. Steady Shot Check
RadarW
RadarW
RadarW
Precautions on the Parts Replacement
There are two types of repair parts.
Type A
ECN-03MA
Type B
ECN-03MB
Replace the broken sensor with a same type sensor. If replace with
other type parts, the image will vibrate up and down or left and
right during hand-shake correction operations.
Precautions on Angular Velocity Sensor
The sensor incorporates a precision oscillator. Handle it with care
as if it dropped, the balance of the oscillator will be disrupted and
operations will not be performed properly.
Subject
Not required
Measurement Point
Displayed data of page: 1 (Note 1)
Measuring Instrument
Adjusting remote commander
Specified value
PITCH data: 2680 to 5080
YAW data: 2680 to 5080
Note 1:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1 : XX : XX
Displayed data
Note 2:
Check that the data of page: 0, address: 10 is “00”.
Switch setting
1) ZOOM ..................................................................... TELE end
2) STEADY SHOT (Menu setting) ....................................... ON
Checking method:
Order Page Address Data
Procedure
PITCH sensor output check (SE6802 of EE-001 board)
1
0
03
11
2
1
With the set in still state,
check that the displayed data
(Note 1) satisfies the PITCH
data specified value.
YAW sensor output check (SE6801 of EE-001 board)
3
0
03
12
4
1
With the set in still state,
check that the displayed data
(Note 1) satisfies the YAW
data specified value.
5
0
03
00
Steady shot operation check
6
Shake the set vertically and
horizontally to check that the
steady shot function operates
normally.