![Sony HDV HVR-A1U Скачать руководство пользователя страница 281](http://html.mh-extra.com/html/sony/hdv-hvr-a1u/hdv-hvr-a1u_service-manual_1323564281.webp)
6-116
HVR-A1J/A1U/A1N/A1E/A1P/A1C
3-3.
SERVO AND RF SYSTEM ADJUSTMENTS
Before perform the servo and RF system adjustments, check that
the specified values of “Origin Oscillation check” of “1-3. CAM-
ERA SYSTEM ADJUSTMENTS” is satisfied.
Check that the data of page: 0, address: 10 is “00”. If not, select
page: 0, address: 10, and set the data “00”.
Adjusting Procedure:
1. CAP FG duty adjustment
2. Switching position adjustment
3. Error rate check
1.
CAP FG Duty Adjustment (TT-001 board)
RadarW
RadarW
RadarW
Set the CAP FG signal duty cycle to 50% to establish an appropri-
ate capstan servo. If deviated, the uneven rotation of capstan and
noise can occur.
Mode
VTR stop (PLAY/EDIT mode)
Signal
No signal
Measurement Point
Displayed data of page: 3, address:
03
Measuring Instrument
Adjusting remote commander
Adjustment Page
C
Adjustment Address
16
Specified value
The data of page: 3, address: 03 is
“00”
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Adjusting method:
Order Page Address Data
Procedure
1
Close the cassette compart-
ment without inserting
cassette.
2
0
01
01
3
3
01
1B
Press PAUSE (Write) button.
4
3
02
Check the data changes in
the following order
“1B”
t
“2B”
t
“00”
5
3
03
Check the data is “00”. (Note 2)
6
0
01
00
Note 2:
If the data is “01”, adjustment has errors or the mecha-
nism deck is defective.
2.
Switching Position Adjustment (TT-001 board)
RadarW
RadarW
RadarW
Mode
VTR playback (PLAY/EDIT mode)
Signal
SW/OL standard (XH2-3)
Measurement Point
Displayed data of page: 3, address:
03
Measuring Instrument
Adjusting remote commander
Adjustment Page
C
Adjustment Address
10, 11, 12, 13
Specified value
The data of page: 3, address: 03 is
“00”
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Adjusting method:
Order Page Address Data
Procedure
1
Insert the SW/OL standard
tape and enter the VTR stop
mode.
2
0
01
01
3
C
10
EE
Press PAUSE (Write) button.
4
3
21
Check the data is “02”. (Note 2)
5
3
01
0D
Press PAUSE (Write) button.
6
3
02
Check the data changes to “00”.
7
3
03
Check the data is “00”. (Note 3)
8
0
01
00
Note 2:
If the data is “72”, the tape top being played. After play-
ing the tape for 1 to 2 seconds, stop it, perform step 5 and
higher.
If the data is “62”, the tape end being played. After re-
wind the tape, perform step 5 and higher.
Note 3:
If bit0 of the data is “1”, the EVEN channel is defective.
If bit1 of the data is “1”, the ODD channel is defective.
Contents of the defect is see written into page: C, ad-
dress: 10 and 12. See following table.
(For the bit values, refer to “6-4. SERVICE MODE”,
“4-4. 3. Bit value discrimination”.)
If bit3 of the data is “1”, the tape end being played, so
rewind the tape and perform the adjustment again.
When the EVEN channel is defective
Data of page: C,
Contents of defect
address: 10
EE
Writing into EEP ROM (IC5402) is
defective
E8
Adjustment data is out of range
E7
No data is returned from IC4001
When the ODD channel is defective
Data of page: C,
Contents of defect
address: 12
EE
Writing into EEP ROM (IC5402) is
defective
E8
Adjustment data is out of range
E7
No data is returned from IC4001
Содержание HDV HVR-A1U