![Sony HDV HVR-A1U Скачать руководство пользователя страница 187](http://html.mh-extra.com/html/sony/hdv-hvr-a1u/hdv-hvr-a1u_service-manual_1323564187.webp)
6-28
HVR-A1J/A1U/A1N/A1E/A1P/A1C
1-3.
CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments, check that the
specified values of “VIDEO SYSTEM ADJUSTMENTS” are sat-
isfied. (Except Origin Oscillation Check”)
Check that the data of page: 0, address: 10 is “00”.
If not, select page: 0, address: 10, and set the data “00”.
1.
Origin Oscillation Check (TT-001 board)
Check the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the color
will become inconsistent.
Subject
Not required
Measurement Point
Pin
5
of IC1403 on TT-001 board
Measuring Instrument
Frequency counter
Specified value
f = 44505000
±
895 Hz (NTSC)
f = 37125000
±
745 Hz (PAL)
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
Checking method:
1) Check that the frequency (f) satisfies the specified value.
Fig. 6-1-6
TT-001 BOARD (SIDE A)
1
4
5
8
IC1403