6-35
HVR-A1J/A1U/A1N/A1E/A1P/A1C
6-2.
Flange Back Adjustment (2)
RadarW
RadarW
RadarW
Perform this adjustment after performing “Flange Back Adjust-
ment (1)”.
Subject
Subject more than 500 m away
(Subject with clear contrast such as
buildings, etc.)
Measurement Point
Adjusting remote commander
Measuring Instrument
Adjustment Page
6F
Adjustment Address
48 to 58
Specified value
Data of page: 6F, address: 57 is“00” to “09”
Data of page: 6, address: 0C is“00”
Note 1:
Perform the adjustment with the lens in horizontal state.
Note 2:
If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 3:
Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Note 4:
Don't touch the zoom lever during adjustment.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHT SHOT .................................................................. OFF
3) COLOR SLOW S (Menu setting) ................................... OFF
4) REC FORMAT (Menu setting) ............................. HDV1080i
Preparations before adjustments:
1) Set the zoom lens to the TELE end and expose a subject that is
more than 500 m away.
(subjects with clear contrast such as building, etc.)
(Nearby subjects less than 500 m away should not be in the
screen)
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
4D
40
3
6
64
04
4
6
14
83
5
6
01
13
Press PAUSE (Write) button.
6
Wait for 2 seconds.
7
Place ND filter on the lens so
that the optimum image is
obtain.
8
6
01
29
Press PAUSE (Write) button.
(Note 5)
9
6
02
Check the data changes to “01”.
10
6
0C
Check the data is “00”.
11
0
10
06
12
F
57
Check the data is “00” to “09”.
(6F)
13
0
10
00
Note 5:
The adjustment data will be automatically input to page:
6F, address: 48 to 58.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
01
25
Press PAUSE (Write) button.
3
6
01
00
Press PAUSE (Write) button.
4
6
14
00
5
6
4D
00
6
6
64
00
7
0
01
00
8
Perform “Flange Back
Check”.