5-39
SEL200600G
9. After the automatic adjustment is completed, message screen is
displayed in the following. Set the infinity jig (1000 mm).
10. “Set to TELE” is displayed, set the zooming ring to the TELE
end (focal length: 600 mm).
Zooming ring
11. When the ENTER key is pressed, automatic adjustment is started.
12. After the automatic adjustment is completed, message screen
is displayed in the following. Set the siemens star chart on the
subject.
13. When the ENTER key is pressed, automatic adjustment is started.
14. After the automatic adjustment is completed, the calculation
processing of the quantity of correction is started. The display
of the message screen changes as follows.
15. When calculation processing of the quantity of correction is
completed, “FSA ADJUSTMENT OK” is displayed.
16. When the ENTER key is pressed, recording the adjustment data
and releasing from adjustment mode are performed automatically,
and “ [FSA ADJUST OK]” is displayed in the message area
when the process is completed.