5-52
3. IR Audio Deviation Adjustment (MI-37 board)
Mode
VTR stop
Signal
Audio signal:
400 Hz, –7.5 dBs: Audio left and
right terminal of A/V jack
Video signal:
Color bar signal: VIDEO terminal
of A/V jack
Measurement Point
AUDIO L terminal and AUDIO R
terminal of IR receiver jig
(Terminated at 47 k
Ω
)
Measuring Instrument
Audio level meter
Adjustment Page
F
Adjustment Address
7F
Specified Value
Signal level: –7.5 ± 1.0 dBs Level
difference of L and R: Below 2 dB
Connection of Equipment
Connect the measuring device as shown in the following figure,
and adjust.
Fig. 5-3-17
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Connect the audio level meter to the AUDIO L terminal of the
IR receiver jig.
3) Select page: F, address: 7F, change the data and set the 400 Hz
audio signal level to the specified value.
4) Press the PAUSE button.
5) Connect the audio level meter to the AUDIO R terminal of the
IR receiver jig.
6) Check that the 400 Hz audio signal level is within the speci-
fied value. If outside, repeat from step 3).
7) Select page: 0, address: 01, and set data: 00.
(75
Ω
)
600
Ω
A/V jack
AUDIO OUT
L
47 k
Ω
47 k
Ω
(1-249-437-11)
600
Ω
(270
Ω
(1-249-410-11) + 330
Ω
(1-249-411-11))
Pattern generator
Video
Audio (L)
Audio (R)
Audio oscillator
Main unit
Attenuator
Audio level meter
VIDEO OUT
R
IR receiver jig
Содержание D8 Digital Handycam DCR-TRV820E
Страница 112: ...DCR TRV820 TRV820E TRV820P 4 77 4 78 USER CONTROL CF 72 ...
Страница 120: ...DCR TRV820 TRV820E TRV820P 4 93 4 94 RGB CG LCD DRIVER TIMING GENERATOR BACK LIGHT PD 118 ...
Страница 134: ...5 5 J 1 J 2 J 3 J 4 J 5 Fig 5 1 1 J 6 J 7 J 8 J 9 J 10 J 11 J 12 J 13 J 14 J 15 J 16 J 17 J 18 ...
Страница 230: ... 295 FOR CAMERA OPTICAL AXIS ADJUSTMENT 0 180 90 67 5 22 5 337 5 292 5 247 5 202 5 157 5 112 5 8 4 5 7 1 6 2 3 270 ...