5-44
3-3.
SERVO AND RF SYSTEM ADJUSTMENTS
Before perform the servo and RF system adjustments, check that
the specified value of “27 MHz/36MHz Origin Oscillation Ad-
justment” of “3-4. VIDEO SYSTEM ADJUSTMENT” is satis-
fied.
Adjusting Procedure:
1. REEL FG adjustment
2. PLL f
0
& LPF f
0
Pre-adjustment
3. Switching position adjustment
4. AGC center level adjustment
5. APC & AEQ adjustment
6. PLL f
0
& LPF f
0
final adjustment
7. Hi8/standard 8 mm switching position adjustment
8. CAP FG offset adjustment
1. REEL FG Adjustment (VC-235 board)
Mode
VTR stop
Measurement Point
Display data of page: 3, address: 03
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
17, 30
Specified Value
Bit values of bit 1 and bit 3
are “0”
Adjusting method:
1) Close the cassette compartment without loading a cassette and
complete loading.
2) Select page: 0, address: 01, and set data: 01.
3) Select page: 3, address: 01, set data: 1C, and press the PAUSE
button of the adjustment remote commander.
4) Select page: 3, address: 02, and check that the data changes to
“00”.
5) Select page: 3, address: 03, and check that bit values of bit 1
and bit 3 are “0”.
If bit value of bit 1 and bit 3 is “1”, there are errors. For the
error contents, see the following table. (For the bit values, re-
fer to “5-4. SERVICE MODE”, “4-3. 3. Bit value discrimina-
tion”)
Bit value of page: 3,
Error contents
address: 03
bit 3 = 1
S REEL is defective
bit 1 = 1
T REEL is defective
6) Select page: 0, address: 01, and set data: 00.
2. PLL f
0
& LPF f
0
Pre-adjustment (VC-235 board)
Mode
VTR stop
Measurement Point
Display data of page: 3, address: 03
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
1F, 20, 22, 29
Specified Value
Bit values of bit 2, bit 3 and bit 6
are “0”
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 3, address: 01, set data: 30, and press the PAUSE
button of the adjustment remote commander.
3) Select page: 3, address: 02, and check that the data changes to
“00”.
4) Select page: 3, address: 03, and check that bit values of bit2,
bit3 and bit6 are “0”.
If bit value of bit 2, bit 3 or bit 6 is “1”, there are errors. For
the error contents, see the following table. (For the bit values,
refer to “5-4. SERVICE MODE”, “4-3. 3. Bit value discrimi-
nation”)
Bit value of page: 3,
Error contents
address: 03
bit 6 = 1
LPF f
0
adjustment is defective
bit 3 = 1
PLL f
0
, fine adjustment is defective
bit 2 = 1
PLL f
0
, fine adjustment is defective
If bit value of bit 2 or bit 3 is “1”, select page: C, address: 21,
set the following data, and press the PAUSE button, and re-
peat steps 2) to 4).
Setting data
When the data of page: C, address: 21 is “CA”
CE
When the data of page: C, address: 21 is “CE”
C6
When the data of page: C, address: 21 is “C6”
D2
When the data of page: C, address: 21 is “D2”
C2
5) Select page: 0, address: 01, and set data: 00.
Содержание D8 Digital Handycam DCR-TRV820E
Страница 112: ...DCR TRV820 TRV820E TRV820P 4 77 4 78 USER CONTROL CF 72 ...
Страница 120: ...DCR TRV820 TRV820E TRV820P 4 93 4 94 RGB CG LCD DRIVER TIMING GENERATOR BACK LIGHT PD 118 ...
Страница 134: ...5 5 J 1 J 2 J 3 J 4 J 5 Fig 5 1 1 J 6 J 7 J 8 J 9 J 10 J 11 J 12 J 13 J 14 J 15 J 16 J 17 J 18 ...
Страница 230: ... 295 FOR CAMERA OPTICAL AXIS ADJUSTMENT 0 180 90 67 5 22 5 337 5 292 5 247 5 202 5 157 5 112 5 8 4 5 7 1 6 2 3 270 ...