5-27
5. Contrast Adjustment (VF-141 board)
Set the level of the VIDEO signal for driving the LCD to the speci-
fied value. If deviated, the screen image will be blackish or satu-
rated (whitish).
Mode
Camera
Subject
Arbitrary
Measurement Point
Pin
qs
of CN259 (EVF VG) on
FU-141 board
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
99
Specified Value
A=2.40 ± 0.1 Vp-p (NTSC model)
A=2.20 ± 0.1 Vp-p (PAL model)
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 99, change the data and set the volt-
age (A) between the pedestal (0 IRE) and 100 IRE to the speci-
fied value.
(The data of address: 99, should be “00” to “7F”)
3) Press the PAUSE button.
4) Select page: 0, address: 01, and set data: 00.
4. RGB AMP Adjustment (VF-141 board)
Set the D range of the RGB driver used to drive the LCD to the
specified value. If deviated, the EVF screen will become blackish
or saturated (whitish).
Mode
Camera
Subject
Arbitrary
Measurement Point
Pin
qs
of CN259 (EVF VG) on
FU-141 board
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
95
Specified Value
A=7.00 ± 0.1 Vp-p
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 95, change the data and set the volt-
age (A) between the reversed waveform pedestal and non-re-
versed waveform pedestal to the specified value.
3) Press the PAUSE button.
4) Select page: 0, address: 01, and set data: 00.
Fig. 5-1-15
Fig. 5-1-14
A
2H
Pedestal
Pedestal
A
2H
100 IRE
Pedestal
Содержание D8 Digital Handycam DCR-TRV820E
Страница 112: ...DCR TRV820 TRV820E TRV820P 4 77 4 78 USER CONTROL CF 72 ...
Страница 120: ...DCR TRV820 TRV820E TRV820P 4 93 4 94 RGB CG LCD DRIVER TIMING GENERATOR BACK LIGHT PD 118 ...
Страница 134: ...5 5 J 1 J 2 J 3 J 4 J 5 Fig 5 1 1 J 6 J 7 J 8 J 9 J 10 J 11 J 12 J 13 J 14 J 15 J 16 J 17 J 18 ...
Страница 230: ... 295 FOR CAMERA OPTICAL AXIS ADJUSTMENT 0 180 90 67 5 22 5 337 5 292 5 247 5 202 5 157 5 112 5 8 4 5 7 1 6 2 3 270 ...