5-47
7. Hi8/standard 8 mm Switching Position Adjustment
(VC-235 board)
If deviated in this case causes switching noise or jitter on the Hi8/
standard 8 mm mode played back screen.
Mode
Playback
Signal
Hi8/standard 8 mm alignment tape:
For tracking adjustment
(WR5-1NP (NTSC))
(WR5-1CP (PAL))
Measurement Point
CH1: Pin
8
of CN259
(VC RF SWP) on FU-141 board
CH2: Pin
5
of CN259 (PB RF) on
FU-141 board
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
62, 63
Specified Value
t1=0 ± 10 µsec
Adjusting Method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: F, address: 22, set data: C0, and press the PAUSE
button of the adjustment remote commander.
3) Select page: 2, address: 2E, and set data: 02.
4) Set to the playback mode.
5) Select page: F, address: 62, change the data and minimize “t1”,
and then press the PAUSE button. (Coarse adjustment)
6) Select page: F, address: 63, change the data and adjust so that
the switching position (t1) becomes the specified value. (Fine
adjustment)
7) Press the PAUSE button.
8) Select page: F, address: 22, set data: 80, and press the PAUSE
button.
9) Select page: 2, address: 2E, and set data: 00.
10) Select page: 0, address: 01, and set data: 00.
Fig. 5-3-7
CH1
CH2
Enlargement
t1=0
±
10
µ
sec
CH1
CH2
8. CAP FG Duty Adjustment (VC-235 board)
Improve the capstan servo characteristic. If it is not correct. jitters
will increase.
Mode
Playback
Signal
Hi8/standard 8 mm alignment tape:
For checking operation
(WR5-5NSP (NTSC))
(WR5-5CSP (PAL))
Measurement Point
Pin
qg
of CN259 (CAP FG) on
FU-141 board
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
64
Specified value
Duty=50 ± 1%
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 2, address: 2E, and set data: 02.
3) Set to the playback mode.
4) Select page: 6, address: 01, set data: 81, and press the PAUSE
button of the adjustment remote commander. (to start up auto-
matic CAP FG offset adjustment)
5) Select page: 6, address: 02, and check that the data is “01”.
6) Check that Duty of CAP FG signal satisfies the specified value.
If not, select page: 6, address: 01, set data: 00, and press the
PAUSE button, and then, repeat steps 4) to 6).
7) Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
8) Select page: 2, address: 2E, and set data: 00.
9) Select page: 0, address: 01, and set data: 00.
Fig. 5-3-8
A
B
Duty = A/B
×
100 [%]
Center of movement
Содержание D8 Digital Handycam DCR-TRV820E
Страница 112: ...DCR TRV820 TRV820E TRV820P 4 77 4 78 USER CONTROL CF 72 ...
Страница 120: ...DCR TRV820 TRV820E TRV820P 4 93 4 94 RGB CG LCD DRIVER TIMING GENERATOR BACK LIGHT PD 118 ...
Страница 134: ...5 5 J 1 J 2 J 3 J 4 J 5 Fig 5 1 1 J 6 J 7 J 8 J 9 J 10 J 11 J 12 J 13 J 14 J 15 J 16 J 17 J 18 ...
Страница 230: ... 295 FOR CAMERA OPTICAL AXIS ADJUSTMENT 0 180 90 67 5 22 5 337 5 292 5 247 5 202 5 157 5 112 5 8 4 5 7 1 6 2 3 270 ...