INIT DATA Menu Item List
This section explains the items in the INIT DATA menu.
SHOW START TIME setting
STRT = 00 00 00 00 to 23 59 59 29
Sets the default R-VTR IN point value for first
edits.
SHOW START TIME is used if the R-VTR IN point
is undefined when the first edit is executed. It is
used to calculate the total time displayed in the
recorder time counter display panel (total time =
recorder IN point timecode - SHOW START
TIME).
Factory default setting: UNDEFINED
Enter a value with the numeric keypad and
confirm by pressing the ENTER button.
If less than 8 digits have been input when the
ENTER button is pressed, the most significant
digits of the 8-digit value are set to 0.
If you press the ENTER button with nothing
displayed in the scratchpad, the message STRT =
UNDEFINED appears and no setting is made.
If you do not specify a show time, the total time
display is based on the recorder IN point of the
first edit (the smallest recorder IN point registered
in the EDL).
Scratchpad display
Status display
INIT DATA
SHOW START TIME
=00 00 00 00 to 23 59 59 29