![Sony BKP-5090 Скачать руководство пользователя страница 76](http://html.mh-extra.com/html/sony/bkp-5090/bkp-5090_installation-and-maintenance-manual_413139076.webp)
4-16 (E)
BKP-5090
Page
Ver.
Item
Settings
Contents
PreKnee/
PreKnee1
XXX (
[XX]
)
Adjusts the R, G or B pre-knee 1 level on the VA board.
Zebra
R/G/B
Aperture
XXX (
[XX]
)
Adjusts the aperture compensation signal level.
y)
White Clip
XXX (
[XX]
)
Adjusts the white clip level.
White Clip
[On]
, Off
Turns the white clip function on and off.
Zebra 1 LEVEL,
XXX (
[XX]
)
Sets the center value and range for the zebra 1 signal detection.
RANGE
Zebra 2 LEVEL
XXX (
[XX]
)
Sets the detection value for the zebra 2 signal.
Z.DISP
1,2, 1&2
Selects a zebra signal to be displayed on the viewfinder.
1
: Zebra 1 signal
2
: Zebra 2 signal
1&2 : Both zebra 1 and 2 signals are displayed at the same time.
Test
1, 2,
[Off]
Selects a test signal to be output in setting each item on the
PreKnee/Zebra page.
1
: Outputs the sawtooth test signal
2
: Outputs the 3-step waveform test signal
Off : No test signal is output
VTR/CCU
VTR R-Y
XXX (
[XX]
)
Adjusts the R-Y color-difference signal level.
VTR B-Y
XXX (
[XX]
)
Adjusts the B-Y color-difference signal level.
CCU Y SAMP
XXX (
[XX]
)
Adjusts the level of the sample pulse to be mixed with the Y signal.
CCU R-Y SYNC XXX (
[XX]
)
Adjusts the level of the sync pulse to be mixed with the R-Y signal.
CCU B-Y SAMP XXX (
[XX]
)
Adjusts the level of the sample pulse to be mixed with the B-Y signal.
RGB Offset
XXX (
[XX]
)
Adjusts the G signal level.
Test
1, 2,
[Off]
Selects a test signal to be output in setting each item on the VTR/CCU page.
1
: Outputs the sawtooth test signal
2
: Outputs the 3-step waveform test signal
Off : No test signal is output
CB
On,
[Off]
Turns on and off the camera color-bar signal to be output in setting
each item on the VTR/CCU page.
IRIS
Level
XXX (
[XX]
)
Adjusts the auto-iris level.
APL Ratio
XXX (
[XX]
)
Sets the way the iris is automatically adjusted.
_
99 (PEAK)
↔
99 (AVERAGE)
(Filter Set)
3200 K, 4300 K,
Set when the color-temperature filter is assigned according to a user’s
1 or A
5600 K, 6300 K
requirement
2 or B
x)
n
The filter indication on the VF screen can not display correctly
3 or C
the selected filter type if this item is improperly set
4 or D
Filter Disk
[AUTO]
, 1, 2
Set corresponding to the filter disc type built in the OHB
After setting, execute the Reference File Store of the Reference
File menu without fail
AUTO: Automatically recognizes the type of built-in filter
1 :
Recognizes the one filter is built in
2 :
Recognizes the two filters are built in
x) Factory setting is as follows:
OHB-400/400P
OHB-405WS/405WSP/500/500P/500WS/500WSP
(One filter built-in)
(Two filters built-in)
1 or A
3200 K
3200 K
2 or B
5600 K
3200 K
3 or C
5600 K
4300 K
4 or D
5600 K
6300 K
y) The adjustment value is cleared by turning off and on the power sequentially because it is the temporary setting value for adjustment.
4-1. Setup Menu (BVP-500 series)
4-1-6. System Config Menu