2-12 (E)
BKP-5090
2-3. Adjustments on BVP-500/500P
2-3. Adjustments on BVP-500/500P
Peripheral equipment
Camera control unit:
CCU-700A/700AP
Master setup unit:
MSU-700
Viewfinder:
BVF-77/77CE
Measuring equipment
Oscilloscope:
Tektronix 2465B or equivalent
Waveform/Vector monitor: Tektronix 1750R or equivalent
(for NTSC)
Tektronix 1751R or equivalent
(for PAL)
Connection and settings during adjustment
Refer to the BVP-500/500P maintenance manual, Section
5 for details.
2-3-1. CCU Y Adjustment
Equipment
: Oscilloscope
Test Point
: TP3(Y)/DA-88A panel
Preparations:
.
S650 (MONITOR SELECT)/IF-538 panel
→
VBS
Adjustment Procedures:
1.
Set the DISPLAY switch/rear panel from OFF to
MENU while pushing up the MENU SELECT switch
to ENTER.
2.
Set the menu as follows.
MENU
: System config
PAGE
: Y/Chroma (S2)
ITEM
: CB
→
On