2-13 (E)
BKP-5090
2-3. Adjustments on BVP-500/500P
2-3-1. CCU Y Adjustment
B
A
B
A
3.
Set the menu as follows and adjust the Y sync using
the MENU SELECT knob/switch.
Adjustment Point
:
MENU
: System config
PAGE
: Y/Chroma (S2)
ITEM
: Y SYNC
Specification
: A = 303
±
2 mV (for NTSC)
A = 300
±
2 mV (for PAL)
4.
Set the menu as follows and adjust the Y video using
the MENU SELECT knob/switch.
Adjustment Point
:
MENU
: System config
PAGE
: Y/Chroma (S2)
ITEM
: Y Video
Specification
: B = 700
±
2 mV
(For NTSC)
(For PAL)
(Waveform Monitor)
(20MHz B/W LIMIT
→
ON)
File Store:
Execute the file store. Throw the MENU SELECT switch
twice to ENTER to execute.
MENU
: Trimming File
PAGE
: Trimming File (T1)
ITEM
: File Store
2-3-2. Test Setup Confirmation (NTSC only)
Equipment
: Waveform monitor
Test Point
: MONITOR connector
Preparations:
.
Connect the waveform monitor to the MONITOR
connector.
.
S650 (MONITOR SELECT)/IF-538 panel
→
VBS
Confirmation:
1.
Set the DISPLAY switch/rear panel from OFF to
MENU while pushing up the MENU SELECT switch
to ENTER.
2.
Set the menu as follows.
MENU
: System config
PAGE
: Y/Chroma (S2)
ITEM
: CB
→
On
3.
Confirm that the test setup “A” is 7.5
±
1 IRE.
4.
If the specification is not satisfied, readjust the test
setup referring to Section 5-4 “Monitor Out Adjust-
ment” in the BVP-500/500P maintenance manual.
(For NTSC)
A