2-4(E)
BVS-A3232
2-5. Backup Battery Replacement
RAM backup battery (BT1) is mounted on the CPU-94
board. Replace the battery with the following as shown in
the part list.
Backup battery : Nickel-cadmium battery
Specifications
Model
GB50H
Voltage
3.6 V
Capacity 50 mAh
Sony Part No. : 1-528-202-11
m
• The battery is guaranteed for the life of three years under
normal condition of usage. Replace the battery within
three years. If the battery runs down, turning off the
power stops the function of internal clock.
• When the optional BKDS-RS1690 is not mounted,
battery replacement deletes the crosspoint data.
(For details on data setting, refer to the supplied Installa-
tion Manual for software.)
Replacement
1.
Turn off the power.
2.
Pull out the CPU-94 board.
3.
Replace the battery (BT1) on the CPU-94 board.
m
• Set the polarity (+) of the battery to the polarity (+) of
the board at soldering.
• Nickel-Cadmium batteries are recyclable.
You can help preserve our environment by returning
your unwanted batteries to your nearest Sony Service
Center or Factory Service Center for collection, recy-
cling or proper disposal.
Note : In some areas, the disposal of nickel-cadmium batteries
in household or business trash may be prohibit.
4.
After Battery Replacement
• When the optional BKDS-RS1690 is mounted, execute
“G: UPDATE BACKUP CONTROLLER” from the
primary station control terminal.
• When the optional BKDS-RS1690 is not mounted,
execute “T: SET CLOCK” from the primary station
control terminal.
(For more details, refer to “5-1. Setting Items of the
Primary Station” in the Installation Manual.)
2-6. DC Fan Motor Replacement
w
For your safety, turn off the power and unplug the power
plug from the outlet before starting the replacement.
Replacement
1.
Remove the top plate. (Refer to “2-1. Removal of
Cabinet”.)
2.
Remove the two screws, then take out the DC fan
cover.
3.
Disconnect the connector (CN2) on the DUS-971
board.
4.
Replace and attach the DC fan in the reverse order of
steps 1 to 3.
m
• Install the DC fan in position the air blowing to rear.
• Hold the cable by the harness clamper to keep the cable
away from the DC fan.
2-5. Backup Battery Replacement
2-6. DC Fan Motor Replacement
BT1
CPU-94 board (A SIDE)
BT1
MA
TSUSHIT
A
SF80 F
AN MOT
OR
5V DC 500mA
DUS-971 board
CN2
DC fan
DC Fan cover
Air flow
Rotative
direction
of Fan
B 4
X
30
Содержание BKDS-PA3291
Страница 6: ......
Страница 26: ......
Страница 38: ......
Страница 48: ......
Страница 78: ......
Страница 96: ......
Страница 102: ...8 6 BVS A3232 8 6 CN 1388 CNB 10 CN 1388 CNB 10 CNB 10 A SIDE 1 661 798 11 CN 1388 A SIDE 1 661 810 11 ...
Страница 103: ...8 7 BVS A3232 8 7 CN 1388 CNB 10 CN 1388 CNB 10 CNB 10 B SIDE 1 661 798 11 CN 1388 B SIDE 1 661 810 11 ...
Страница 104: ...8 8 BVS A3232 8 8 HN 237 HN 237 HN 237 A SIDE 1 661 799 11 ...
Страница 105: ...8 9 BVS A3232 8 9 HN 237 HN 237 HN 237 B SIDE 1 661 799 11 ...
Страница 106: ...8 10 BVS A3232 8 10 HN 238 HN 238 HN 238 A SIDE 1 661 800 11 ...
Страница 107: ...8 11 BVS A3232 8 11 HN 238 HN 238 HN 238 B SIDE 1 661 800 11 ...
Страница 108: ...8 12 BVS A3232 8 12 MB 721 MB 721 MB 721 A SIDE 1 661 801 11 ...
Страница 109: ...8 13 BVS A3232 8 13 MB 721 MB 721 MB 721 B SIDE 1 661 801 11 ...
Страница 118: ......
Страница 124: ...9 14 BVS A3232 9 14 2 3 4 5 A B C D E F G H 1 ...
Страница 134: ...9 24 BVS A3232 9 24 2 3 4 5 A B C D E F G H 1 ...
Страница 138: ......