Using the Camera Tally
Function
You can have the tallies on cameras light via the VISCA
and GPI connectors at the rear of the unit when the
camera’s video is being used as the PGM output or NEXT
selection source in the [Input] list or [Title] list.
The cameras that are compatible with the tally function
and the lighting conditions are as follows.
• The tallies on remote cameras do not support lighting in
response to NEXT selection.
• Tallies will light or turn off when [Take] is tapped,
regardless of transition settings.
• This function does not apply to selections made in the
[AUX] list.
Lighting Tallies on Remote
Cameras
Connect the remote cameras and assign them to video
input connectors.
For details on connecting cameras and assigning them to
video input connectors, see “Remote Camera
Connections and Settings” (page 93).
Lighting Tallies on Cameras
Connected via GPI
Connect the unit’s GPI connector to the TALLY
connector on a CCU, for example, and configure the
conditions for GPI output. The tallies on the camera will
light in response to the GPI outputs.
This function supports up to four cameras.
1
Connect the camera to the unit.
2
Connect the GPI connector on the unit to the TALLY
connector on the CCU.
For details on pin assignments on the GPI connector,
see “GPI connector” (page 113) in the “Connector
Pin Assignments” section.
3
Select the input source of the camera in the [Input] list
of the main screen, and verify the video.
4
Display the [System Setup] screen in the sub screen,
and tap [Others].
5
Tap [GPI] to display the [GPI] screen.
6
Specify the GPI output conditions for each pin on the
GPI connector.
[GPI OUT 1] to [GPI OUT 4]:
Specify the
conditions for GPI output.
•
[Not Assigned]:
Do not use this function.
•
[PGM Tally Input1] to [PGM Tally Input6]:
GPI output occurs when video from the selected
camera is being used as the PGM output source.
•
[NEXT Tally Input1] to [NEXT Tally
Input6]:
GPI output occurs when video from
the selected camera is being used as the NEXT
selection source.
Camera
Lighting
condition
Setting
Remote cameras
(VISCA connection)
• In use as
PGM output
Not required
Cameras connected to
the GPI connector on the
unit via the TALLY
connector on a CCU, for
example
(GPI connection)
• In use as
PGM output
• In use as
NEXT
selection
Required