Data Integrity/Media Management
The System Log pages shown in the MIC layout (Figure F-2) capture significant media and data integrity statistics,
such as load counts, access counts and error correction counts (ECC). Media management software can utilize this
information and proactively copy and retire media volumes approaching the end of their useful life. Unlike other
technologies that need to capture these statistics on-tape or in a host database, the MIC-based media management
system keeps the statistical information together with the media cartridge, yet it physically separates the information
from the tape itself. This makes it possible to maintain and access the information even after the media is
reformatted or damaged. Since some of the information is maintained even when the Write Protect Tab is enabled,
the statistics are always accurate.
14.2.3.1.
Sample Application for MIC
Most applications maintain the index/vendor information at the bottom of user data on the tape or in a separate
partition. This results in the necessary periodic positioning operations, which consume much operational time and
result in media and mechanical wear. If the index information is small enough to fit the available user memory in MIC
(less than 6,561 bytes for the 64 kbits version of AIT-E Turbo, AIT-1 Turbo contact type of MIC), it can readily be
maintained in the User Data Area. This method should result in significantly improved operational times and longer
media and device life.
Note:
Hardware data compression is not available for MIC data.
MIC provide UVN and UPN those are independent storage area from tape. You can write your data to MIC without
any modification for tape.
Содержание AIT-SDX460
Страница 4: ...This page intentionally left blank ...
Страница 10: ...SDX 460V series Ver 1 0 Table of Contents This page intentionally left blank ...
Страница 28: ...3 Installation SONY AIT 1 Turbo drive SDX 460V series Ver 1 0 3 6 This page intentionally left blank ...
Страница 38: ...4 Operation SONY AIT 1 Turbo drive SDX 460V series Ver 1 0 4 10 This page intentionally left blank ...
Страница 164: ...8 Drive Diagnostics SONY AIT 1 Turbo drive SDX 460V series Ver 1 0 8 10 This page intentionally left blank ...
Страница 180: ...14 Appendix F SONY AIT 1Turbo drive SDX 460V series Ver 1 0 14 6 This page intentionally left blank ...
Страница 192: ...16 Appendix H SONY AIT 1Turbo drive SDX 460V series Ver 1 0 16 4 This page intentionally left blank ...