7. ATAPI Packet Command Specification
RECEIVE DIAGNOSTIC RESULTS
SONY AIT-1Turbo drive SDX-460V series Ver.1.0
7-56
7.14. RECEIVE DIAGNOSTIC RESULTS 1Ch
Bit
Byte
7 6 5 4 3 2 1 0
0
Operation Code (1Ch)
1
Reserved
2
Reserved
3
(MSB)
4
Allocation Length
(LSB)
5
Reserved
6
Reserved
7
Reserved
8
Reserved
9
Reserved
10
Reserved
11
Reserved
RECEIVE DIAGNOSTIC RESULTS requests error analysis data be sent to the initiator after completion of a SEND
DIAGNOSTIC command.
Allocation Length:
This field specifies the number of bytes that the initiator has allocated for returned diagnostic
data. An Allocation Length of ZERO means that no diagnostic data will be transferred. Any other value indicates
the maximum number of bytes that will be transferred.
If the SEND DIAGNOSTIC had the PF bit set, the drive returns four bytes of header data as will as eight bytes of
the diagnostic result. If the PF bit was not set, the drive returns only the eight bytes of the diagnostic result.
The drive terminates the data transfer when Allocation Length bytes have been transferred or when all the
available diagnostic data (four or eight bytes depending on the PF bit) have been transferred to the host,
whichever, is less.
If the drive returns a CHECK CONDITION status with the HARDWARE ERROR Sense Key and an Additional
Sense Code of DIAGNOSTIC FAILURE set on completion of a SEND DIAGNOSTIC, then the Host should issue a
RECEIVE DIAGNOSTIC RESULTS command to receive the eight bytes of data indicating the actual failure and
the Most Suspect Unit (MSU).
If the Host issued a SEND DIAGNOSTIC with the PF bit set and a page Code of ZERO, the drive returns which
pages it supports in the following format:
Table 7-52: Receive Diagnostics supported pages
Bit
Byte
7 6 5 4 3 2 1 0
0
Page Code (00h)
1
Reserved
2
(MSB)
3
Page Length (00 002h)
(LSB)
4
Supported Page Code (00h)
5
Supported Page Code (81h)
Содержание AIT-SDX460
Страница 4: ...This page intentionally left blank ...
Страница 10: ...SDX 460V series Ver 1 0 Table of Contents This page intentionally left blank ...
Страница 28: ...3 Installation SONY AIT 1 Turbo drive SDX 460V series Ver 1 0 3 6 This page intentionally left blank ...
Страница 38: ...4 Operation SONY AIT 1 Turbo drive SDX 460V series Ver 1 0 4 10 This page intentionally left blank ...
Страница 164: ...8 Drive Diagnostics SONY AIT 1 Turbo drive SDX 460V series Ver 1 0 8 10 This page intentionally left blank ...
Страница 180: ...14 Appendix F SONY AIT 1Turbo drive SDX 460V series Ver 1 0 14 6 This page intentionally left blank ...
Страница 192: ...16 Appendix H SONY AIT 1Turbo drive SDX 460V series Ver 1 0 16 4 This page intentionally left blank ...