7. ATAPI Packet Command Specification
READ POSITION
SONY AIT-1Turbo drive SDX-460V series Ver.1.0
7-54
7.13. READ POSITION 34h
Bit
Byte
7 6 5 4 3 2 1 0
0
Operation Code (34h)
1
Reserved TCLP
LONG
BT
2
Reserved
3
Reserved
4
Reserved
5
Reserved
6
Reserved
7
Reserved
8
Reserved
9
Reserved
10
Reserved
9
Reserved
The READ POSITION command reports the current logical position of the Device. No medium movement shall
occur as a result of the command.
TCLP:
The Total Current Logical Position (TCLP) bit of ONE indicates the drive shall return data specifying the
partition, file, and set number with the current logical position. The TCLP bit of ZERO indicates the drive shall
return data specifying the first and last block location with the number of bytes and blocks in buffer.
LONG:
The Long Format (LONG) bit of ONE indicates the drive shall return 32 bytes of data. The LONG bit of
ZERO indicates the drive shall return 20 bytes of data.
The LONG bit and the TCLP bit shall be equal. If the LONG and TCLP bits are not equal, or if both the LONG and
the Block Address Type (BT) bits are ONE, the command is rejected with a CHECK CONDITION status and an
ILLEGAL REQUEST sense key set.
BT:
The Block Address type (BT) bit controls the content of the short format data. The BT bit if one requests the
drive to return its current First Block Location shall include data block only. The BT bit of ZERO requests the drive
to return the First Block Location as a Logical Block Address (data blocks, File-marks and Save Set Marks are
counted.)
The READ POSITION data shown in Table 7-50: Read Position Data Format shall be returned as data after the
command.
Table 7-50: Read Position Data Format, short form
Bit
Byte
7 6 5 4 3 2 1 0
0
BOP EOP
Reserved
1
Partition Number
2
Reserved
3
Reserved
4
(MSB)
5
6
7
Block Address
(LSB)
8-19
Reserved
BOP:
A Beginning Of Partition bit of one indicates that the Device is at the
beginning-of-partition
in the current
partition. A
BOP
bit of zero indicates that the current logical position is not at the
beginning-of-partition
.
EOP:
An End Of Partition bit of one indicates that the Device is positioned between
early-warning
and
end-of-
partition
in the current partition. An
EOP
bit of zero indicates that the current logical position is not between
early-
warning
and
end-of-partition
.
Partition Number: r
eports the partition number for the current logical position.
Содержание AIT-SDX460
Страница 4: ...This page intentionally left blank ...
Страница 10: ...SDX 460V series Ver 1 0 Table of Contents This page intentionally left blank ...
Страница 28: ...3 Installation SONY AIT 1 Turbo drive SDX 460V series Ver 1 0 3 6 This page intentionally left blank ...
Страница 38: ...4 Operation SONY AIT 1 Turbo drive SDX 460V series Ver 1 0 4 10 This page intentionally left blank ...
Страница 164: ...8 Drive Diagnostics SONY AIT 1 Turbo drive SDX 460V series Ver 1 0 8 10 This page intentionally left blank ...
Страница 180: ...14 Appendix F SONY AIT 1Turbo drive SDX 460V series Ver 1 0 14 6 This page intentionally left blank ...
Страница 192: ...16 Appendix H SONY AIT 1Turbo drive SDX 460V series Ver 1 0 16 4 This page intentionally left blank ...