![Sonifex S0 v2 Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/sonifex/s0-v2/s0-v2_handbook_1321165028.webp)
18
3 Configuration Options
3. Configuration Options
The S0 v2 has a range of configuration options that allow different aspects
of the mixer’s operation to be customised. This can be done using the
Sonifex SCi software that runs on a PC, or through a dedicated setup mode
on the mixer itself.
Modifying the Configuration Options Using Setup Mode
The setup mode allows the configuration options to be modified directly,
without the need to connect the S0 v2 to a PC. The configuration settings
are presented in pages, with the current page displayed on the PPM scale
on the LED meters display. To change a setting, first select the relevant
page, then using the details in the table below, press the relevant button to
select the required option setting. The buttons used to select the settings
will continually flash a number of times to indicate the current setting. For
example, for a setting with mode 4 selected, a button would repeatedly
flash 4 times with a short pause between each sequence of 4 flashes.
To Enter Setup Mode:
1.
Ensure all faders are closed.
2.
Press and hold the Monitor, Presenter and Guest AUTO CUE/PFL
buttons.
3.
Press the Monitor PGM button 5 times within 2 seconds.
4.
A single sweep on the LED meters indicates that setup mode has been
entered and the buttons can be released.
To change the current page, press the Guest TALKBACK button. The LED
meters display will indicate the new page on the PPM scale.
To Exit Setup Mode:
1.
Press and hold the Guest TALKBACK button for 2 seconds.
2.
A dual sweep on the LED meters indicates return to normal operation
and the button can be released.
To return all configuration options to the default settings:
1.
Remove power from the unit.
2.
Ensure all faders are closed.
3.
Press and hold the Monitor REC, Monitor AUTO CUE/PFL, Presenter
AUTO CUE/PFL and Guest AUTO CUE/PFL buttons.
4.
Apply power to the unit. A single sweep on the LED meters indicates
that the configuration options are being returned to defaults. The
buttons can be released.
5.
A dual sweep on the LED meters indicates return to normal operation.
Page 1 – Input Select Modes (LED on PPM Scale 1)
Channels 1-4 Input Select Modes are set using the MIC/LINE buttons for
each channel.
Mode 1 MIC & LINE inputs available for selection. Phantom power is off
(default for channels 2-4).
Mode 2 MIC & LINE inputs available for selection. Phantom power is on
(default for channel 1).
Mode 3 MIC input only, the button is disabled. Phantom power is off.
Mode 4 MIC input only, the button is disabled. Phantom power is on.
Mode 5 LINE input only, the button is disabled. Phantom power is off.
Channels 5-8 Input Select Modes are set using the INP1/INP2 buttons.
INP1 refers to the line input with the lower number on the channel i.e. on
Содержание S0 v2
Страница 1: ...Manufacturers of audio video products for radio TV broadcasters S0 v2 Radio Broadcast Mixer HANDBOOK...
Страница 35: ...25 Configuration Options 3 Reset Switch Fig 3 5 Reset Switch...
Страница 50: ...Notes...
Страница 51: ...Notes...
Страница 52: ...www sonifex co uk t 44 0 1933 650 700 f 44 0 1933 650 726 sales sonifex co uk...