7-9
(xiii) Jumper pin for determining contact signal output operation
In JP1 setting, the operation of the contact signal output is determined. Please
change the setting as necessary.
Table: JP1 setting (operation of the contact signal output)
JP1 setting
Operation of the contact signal output
1-2 shortcut
(before
shipment)
The contact is ON when the hoisting system is at the
upper limit.
2-3 shortcut
The contact is ON when the hoisting system is in
operation (ascending/descending).
Open
The contact is always OFF.
(xiv) TB201 connector (CB561)
Connector for connecting the CB561 cables
Table: TB201 pin assignment
TB201
CB561
wire color
Signal name
Signal direction
1
Brown
HOLD
Processor → hoisting
system
2
Red
FALL
Processor → hoisting
system
3
Orange
BUZZER
Processor → hoisting
system
4
Yellow
GND_ISO
-
5
Green
LOWER_LIMIT_ISO
Hoisting system →
processor
6
Blue
UPPER_LIMIT_ISO
Hoisting system →
processor
7
Light blue CLINO
Processor → hoisting
system
8
Gray
CLINO_ON_OFF−
Processor → hoisting
system
9
White
CLINO_422A
Hoisting system →
processor
10
Black
CLINO_422B
Hoisting system →
processor
Содержание SCS-60
Страница 1: ...Model SCS 60 Scanning Sonar Operation Manual Ver 5 00E Rev 0...
Страница 2: ...MEMO...
Страница 12: ...x MEMO...
Страница 16: ...1 4 MEMO...
Страница 32: ...4 6 MEMO...
Страница 45: ...5 13 A display example of Net Cat Net Set and VRM Wake Net Cast mark Net Set mark VRM VRM distance...
Страница 50: ...5 18 MEMO...
Страница 70: ...6 20 MEMO...
Страница 86: ...7 16 MEMO...
Страница 94: ...8 8 MEMO...