SAI 2000W
Before using the product for the first time, please read
the instructions for use below and retain them for later
reference. The original instructions were written in the
Hungarian language.
This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities, or
lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a person
responsible for their safety. Children should be supervised at all times to
ensure that they do not play with the appliance.
After unpacking the unit, confirm that it has not been damaged during transit.
Keep the packaging away from children if it contains plastic bags or other potentially
hazardous components.
MAIN FEATURES
• 12 V DC / 230 V AC voltage converter (inverter) • Audible warning and automatic power off
when battery becomes depleted • Overload and overheat protection • Overload and output short-
circuit protection • Ideal for powering AC powered appliances where only 12 Volts DC power is
available such as computers, radios, TV sets, VCRs, lights, fans, electric razors, power tools,
battery chargers, etc. in vehicles, on board boats, camp sites or elsewhere
INSTALLATION
1. Unscrew and remove the plastic screws and washers of the red and black connectors on
the rear of the unit. Place the terminal of the corresponding connecting cable onto the
appropriate screw then put the washer on. Then tightly fasten the cables using the plastic
screws.
2. Tightly connect the other end of the cables directly to the 12V battery’s terminals. Make
sure that the connection is tight and the polarity is correct.
3. Connect the AC powered unit to the inverter.
4. Switch the inverter on (“I” position).
5. Switch on the AC powered equipment to be operated.
6. After use switch off the AC powered equipment first then switch off the inverter.
This unit should only be operated using the included connecting cable. Do not modify or extend it.
Do not use a cigarette lighter cable over a power requirement of 300W. The inverter must be
directly connected to the battery as specified. Make sure the polarity indicated (red: positive,
black: negative) is observed and the connections are secure and solid. Depending on the vehicle
new battery terminal connectors might need to be purchased.
Should the vehicle’s battery be drained excessively during use, an audible warning will sound. In
this case switch off the equipment connected to the inverter then the inverter itself. Disconnect the
12V connection then start the vehicle’s engine in order to recharge the battery. If the equipment is
continued to be used despite the audible warning, the inverter’s output will soon switch off
automatically in order to protect the battery.
In order to prevent the excessive discharging or overcharging of the battery, it is recommended to
run the engine for 10-20 minutes after every 2 or 3 hours of inverter usage. Before starting the
engine switch off the equipment and disconnect the inverter from the vehicle.
Notes:
On being switched on, certain pieces of equipment briefly draw much more current than during
normal operation. In such cases the equipment might need to be switched on then off several
times for it to operate properly. This is typical of high current TV sets when being powered off low
capacity inverters, for example.
For the sake of stable operation, when equipment containing motors is being used (such as
compressors, drills, air conditioners, etc.), the inverter’s capacity should be triple that of the
equipment’s power requirement.
The inverter automatically switches off if the power requirement of the equipment being operated
exceeds the inverter’s capacity. This also happens in the case of overheating. The unit features
additional protection from reverse polarity battery connection and output short circuit.
CABLE EXTENSIONS
The 12 V connecting cable is not recommended to be extended due to power loss associated with
increasing voltage drop. Instead an up to 30m quality extension cable can be used to lead the
mains voltage from the inverter to the unit to be operated. Any longer cord may cause power loss.
CHECKING THE MAINS VOLTAGE
The waveform of the mains voltage created by the inverter is a modified sine wave. Only a
calibrated RMS Voltmeter will provide an accurate measurement result. Other kinds of measuring
devices may measure 20-30V less than the actual voltage.
PROTECTION
The unit has been equipped with multiple safety features. The mains voltage is cut off on
activation. In this case proceed as follows:
1. Turn off the equipment being operated.
2. Turn off the inverter.
3. Pull out the plugs.
4. Check the AC powered equipment’s rated power and proper connection.
5. Use the equipment again once the problem has been resolved. If required, seek the help of a
professional.
The mains output can cut off after long periods of continuous operation even if the battery’s charge
is appropriate. This may be due to overheating. In this case proceed as follows:
1. Turn off the equipment being operated.
2. Turn off the inverter.
3. Wait for it to cool down.
4. Turn it back on later.
The internal fuse can blow in the event of short circuit or reverse polarity connection. In this case seek
the help of a professional. Be sure to use a fuse with the same rating as the original.
MAINTENANCE
Regularly check the connection that they are tight and clean them if necessary. Use only a soft, dry
cloth to clean the unit.
WARNINGS
• If necessary, prior to first use seek professional assistance so as to prevent damaging the
unit or the connected devices.
• Check that the DC voltage available is 12V and whether the unit to be operated requires
230V AC voltage.
• More than one AC powered appliances can be powered at the same time using a multiple
socket outlet connected to the inverter. In order to prevent overloading make sure that the
maximum load limit is not exceeded. Check the rating label of the equipment to confirm.
• Make sure that the 12V power supply is connected in proper polarity.
• The connections should be stable and short-circuit free.
• No foreign objects should get between the fan blades.
• Do not cover the unit and position it to ensure there is a free flow of air.
• Leave 20cm of free space behind the fan in order to ensure its effective operation.
• The inverter can be damaged if it is switched off while the appliance connected to it is still
running.
• The inverter can be damaged if the appliance connected to it is switched on before the
inverter is switched on.
• Switch off the inverter and disconnect it from the circuit when it is not being used. Do not
leave it connected to the vehicle’s power circuit.
• In the event of particularly extended use, or when higher capacity equipment is being
operated, it is recommended to run the vehicle’s engine from time to time in order to prevent
depleting the battery.
• Before starting the engine switch off the equipment then the inverter and disconnect the
inverter from the vehicle’s electric system.
• Disconnect the inverter from the battery before starting to recharge it using a battery charger.
• Do not disconnect the inverter from a battery being charged.
• Do not connect the inverter’s input to a battery charger.
• Do operate without supervision and keep out of reach of children.
• When leading the connecting cables make sure not to damage their insulation.
• Observe the usual safety precautions as the unit’s output voltage can cause electric shock.
• In case of any anomaly, immediately power off the unit and seek the assistance of a
specialist.
• Protect the appliance from dust, humidity, liquids, heat, moisture, frost and shock as well as
from direct heat and sunlight.
• Do not attempt to disassemble of modify the unit. Due to the presence of AC power, observe
the usual precautions to prevent risk to life. Do not touch the unit or power cable with wet
hands.
• If the AC power cable is damaged, immediately power off the unit.
• The unit may switch off automatically more frequently in a warm environment even if the load
is negligible.
• The unit may only be used in dry conditions.
• Failure to observe the warnings or using the unit improperly can damage the unit, which will
void the warranty.
• Do not disassemble or modify the unit as this may cause fire, accident or electric shock.
• Due to ongoing improvements and development, the specifications and design are subject to
change without notice.
• We assume no responsibility for printing errors and apologize if they should occur.
PROVISION OF PROTECTIVE GROUNDING
Before putting the inverter to use, a protective grounding shall be provided just as in the case of
household use.
When used at a fixed location:
There is a screw on the rear of the unit under the negative terminal which is connected to the case,
the protective grounding terminal of the power socket and the appropriate point of the printed
circuit board. Normally this screw should be grounded by connecting it to a metal rod stuck at least
1.2m deep into the ground and with a proper contact.
When used in a vehicle:
The ground cable must be connected to the vehicle’s negative ground contact (chassis). (Only if
the vehicle has a negative ground contact.) If the vehicle has a positive ground contact, the
positive (red) terminal must be connected. If the AC powered equipment to be operated is not
located inside the vehicle, the above-mentioned grounding rod must be used.
When used on board a boat, it must be connected to the grounding cable of the electric circuits
(e.g., motor) on board.
SPECIFICATIONS
Power output, continuous: 1.000 W (230 V AC / 50 Hz)
Power output, peak: 2.000 W (230 V AC / 50 Hz)
Input voltage range: 12 V (10,5–15 V)
Output waveform: modified sine wave
Efficiency: 85–90%
Dimensions/weight: 150 x 60 x 300 mm / 1,5 kg
voltage converter
Red power indicator LED & audible signal
Green indicator LED
Beeping under 10, 5 V
Illuminates and beeps under 9,5 V
and then the output switches off
Illuminates and switches off over 15 V
Operation indicator
Dropping input voltage
Low input voltage
High input voltage