19
EN
- SLIDYMOOVE 300 installation and operating guide - SOMFY
E
N
3.1 Photoelectric cells
It is not possible to connect a second set of photoelectric cells on this drive.
TX
1
2
1
2
3
5
RX
B
U
S
BUS
33
44
Installation
A"er wiring the photoelectric cells:
•
switch the motor on again,
•
start a gate opening or closing procedure.
The photoelectric cells are recognised by the
control electronics once this movement is
complete.
Operation with photoelectric cells
If the cells are blocked when closing the gate,
the gate will stop and reopen.
10 W - 24 V bulb MAXIMUM - use of a bulb with power greater than 10 W- 24 V can cause drive
malfunctions.
3.2 Orange light
Operation of the orange light
The orange light flashes while the gate is moving.
For your safety, these operations must be carried out with the power supply switched off.
You are advised to perform auto-programming of the gate travel before connecting the accessories
(photoelectric cells, orange light, etc.)
WIRING THE ACCESSORIES
3
FR