21
EN
3V
CR 2430
+
[1].
Remove the clip on
the remote control.
[2].
Lift the
cover.
[3].
Remove the battery
using a screwdriver.
[4].
Replace the battery
(3V CR 2430).
3V
CR 2430
+
3V
CR 2430
+
diagnostics
rEPairs
5 pulses
Motor thermal
protection device
activated
Allow the motor to cool down until the STATUS
indocator lights up continuously.
6 pulses
Short circuit on the
electronic unit 24 V
output (terminals 5-6)
Check the accessory connected to the electronic unit
24 V output.
Short circuit of orange
light (terminals 7-8) on
the electronic unit
Check the wiring of the orange light
(see page 16).
Motor short circuit
Check the motor wiring (see page 2).
the automatic
closing mode
does not activate
(the auto closE
indicator
stays
off).
Photoelectric cells not
installed
Install some cells (see pages 12 and 13).
Replacing the remote control battery
►
The service life of the battery is generally 2 years.
Never dispose of used batteries with household waste. They must be placed in a specific
recycling bin.
Aerial
aerial wiring and position
►
The aerial must be connected to terminal 1 of the motor electronics
and be positioned as shown in the illustration opposite.