20
EN
trouBlEshooting guidE
Power the installation off during cleaning operations or other maintenance operations.
diagnostics
rEPairs
the motors are not
responding to remote
control commands
The remote control
range is reduced
- Check the remote control battery (see "Changing
the remote control battery, next page).
- Check the aerial of the electronic unit (wiring,
position, see next page).
- Check that there are no outside elements that
are interfering with the radio signal (electric
pylon, metal reinforced walls, etc.). If this is the
case, fit an external aerial.
Remote control not
memorised
Memorise the remote control (see page 9).
1 or 2 motors unlocked Lock the motors.
the electronic unit's
status
indicator is off
Motor not powered
- Check the power supply.
- Check the supply cable.
Outdoor lighting very
low = motor on standby
Increase the light around the electronic unit
(using a torch, for example) if you want to make
adjustments.
the status
indicator
of the electronic unit is
flashing:
1 pulse
Operation using the
backup battery
Check the power supply.
2 pulses
Motor waiting for
gate travel to be
programmed
Begin the programming of the gate leaves' travel
(see page 4).
3 pulses
Cell fault:
- Cells blocked
Remove the obstacle blocking the cells.
- Cells misaligned
Correct their alignment (see instructions supplied
with the cells).
- Cells incorrectly wired Wire the cells following the instructions on
page 13.
- Cells missing/
disconnected
- Check that your cells are correctly connected.
- If you have deliberately disconnected the cells
and your gate is operating in auto close mode,
you must deactivate auto close mode
(see page 10).
4 pulses
Short circuit on the
electronic unit BUS
output (terminals 3-4)
Check the accessories connected to the