3
EN
connection to the electrical power supply
►
For your safety, these operations must be carried out with the power supply switched off.
[1].
Strip the supply cable wires
(same length for the 3 wires).
[2].
Connect the earth wire.
An earth wire (green/yellow) and the insulated
terminal provided must be used for certain
accessories (230 V lighting Class I).
[3].
Connect the live (L) and the neutral (N) between
terminals 15 and 16 of the electronic unit (red
230 V label).
Check that the wires are correctly secured in place
by pulling them gently upwards.
terminal
Blue wire
N
15
Red/brown/black wire
L
16
Green and yellow wire
The colour-coding of the wires must be
followed.
connection to a solar power supply
►
See page 19
safety device connection
►
Photoelectric cells must be installed and connected before beginning to commission the motor (See
page 4).
connection to the mains power supply
►
Before beginning to commission your equipment, the electronic unit must be connected to the
mains power supply.
15
16
230V
N
L
8 mm
75 mm