Once the 2600 / VI is connected to the router, the
user accesses the Virtual Interface Control from
any computer on the LAN, using a web browser
and typing in the address bar the following:
2600XD/
•
If the connection is successful the login screen
of the 2600 / VI appears. See "3.8.2 - Virtual
Interface" on instructions from the Virtual Con-
trol Interface
•
If the login screen does not appear:
a) Check the connection of the console to
the router on the LAN and try again.
b) Use the "Solidyne IP Discovery" tool to
find the IP address of the console. Enter
the IP address in a browser to access
the Control Interface.
3.9.1 Solidyne IP Discovery
If due to network settings can not access the con-
sole using the generic name "2600XD /"; must be
accessed using the IP address. The IP Discovery
Tool lets you know the current IP of the console.
Download the following file:
solidynepro.com/DW/
IP
.exe
The file is a self-extracting ZIP. When run is cre-
ated in the local folder a sub-folder called "Soli-
dyne IP discovery" that contains the applications
and instructions. Look in that folder the
"readme.txt" file and follow the steps as required.
Once the 2600's IP address is obtained; enter it in
a WEB browser to access the "Virtual Interface
Control.
IMPORTANT:
The "IP Discovery" tool also must be
used when:
•
You want to
connect the console directly
to a computer
using a crossover cable (no
LAN) for operational tests or demonstrations.
•
DHCP is disabled and an unknown fixed IP
is set to the 2600/VI, being outside the range
of the LAN. In this case "IP Discovery" will be
used to find the current IP address to access
the Control Panel (either to enter a valid IP
address or enable DHCP).
For details about direct connection using cross-
over cable, please refer to the additional docu-
mentation included with the IP-Discovery.
3.9.2 Accessing to Virtual Interface
To access to the control panel,
user name
and
password
are required. There are five factory
users: user1; user2; user3; user4 and user5; be-
ing the default password for all '1234
Click "Login" to access the control interface. The
option "Advanced" allows to access the configura-
tion options, which are detailed below.
solidynepro.com
Broadcast mixing consoles - 2600 series
Page 33
Содержание 2600 serie
Страница 1: ......
Страница 2: ...Page 2 Broadcast mixing consoles 2600 series solidynepro com...
Страница 4: ...This page is intentionally left blank Page 4 Broadcast mixing consoles 2600 series solidynepro com...
Страница 41: ...5 2 Bock diagrams solidynepro com Broadcast mixing consoles 2600 series Page 41...
Страница 42: ...Page 42 Broadcast mixing consoles 2600 series solidynepro com...
Страница 43: ...solidynepro com Broadcast mixing consoles 2600 series Page 43...