5. Using a 9/16" deep socket remove and replace the
burner orifices with correct orifice provided in the
conversion kit.
Note: The FORTY8 model only has one burner orifice.
6. When converting to propane, remove collar on
burner inlet tube. When converting to natural gas
install collar over burner inlet tube and secure with
#8 sheet metal screw provided using a 1/4" nut driver.
7. Remove the (2) #10 sheet metal screws using a 5/16"
nut driver that hold the pilot assembly in the fireplace.
8. Lift the pilot assembly into the fireplace which
will give you access to the fittings under the pilot
assembly. Take extra caution to not damage ceramic
electrode on pilot assembly.
9. Using a 10mm wrench, remove the pilot gas line and
swap the pilot orifice with the one supplied in the
conversion kit. Be sure that the pilot orifice is fully
seated and the pilot gas line is tightened properly
to prevent leaks around the orifice. If not seated
properly this will cause an unusually high pilot flame.
10. Once the pilot gas line is tightened, reinstall the pilot
assembly in the fireplace using the two #10 sheet
metal screws provided. Ensure pilot gasket is intact.
11. Reinstall the burners in the fireplace and the burner
link (if required) with #10 sheet metal screws using a
5/16" nut driver.
(continued on next page)
GAS CONVERSION
Collar OFF for LP
Pilot orifice
correctly sealed
Collar ON for NG