![SolarEdge StorEdge SE7600A-US1 Скачать руководство пользователя страница 97](http://html1.mh-extra.com/html/solaredge/storedge-se7600a-us1/storedge-se7600a-us1_installation-manual_1313757097.webp)
o
White CT wire is connected to L1 white
o
Black CT wire is connected to L1 black
l
CT direction is towards the grid and the green power LEDs are ON. If the LEDs are not green indicating
import power - the CTs are reversed.
Figure 43: Meter with CTs
Battery Troubleshooting
The State line in the battery status screen should display one of the following: Charging, Discharging, Idle,
Off, Init.:
B S N : X X X X X X X X X I D : 1 5
S O E : 8 9 %
W W W W
P W R : 2 W
T o t a l : < x > W h
S t a t e : C h a r g i n g
l
If error code
3x6B
(or
Error 186
) -
Battery Comm. Error
appears, the battery communication is
disconnected. Check the following:
o
The RS485 control connection to the battery
o
The communication DIP switches settings on the battery
o
The ID DIP switches setting on the battery
l
If the state
Idle
is displayed instead of Charging/Discharging, check the following:
o
The system configuration
o
The DC connection
o
The LEDs in the Connection Unit - refer to
l
If
Battery Internal Fault
is displayed, refer to the battery documentation supplied with it. The
following is an example fault screen.
B a t t e r y I n t e r n a l
F a u l t < # > ( I D : 1 5 )
< x x x x >
Fault # - according to battery
ID - The Modbus ID of the battery
<xxx> - text
Appendix A: Troubleshooting
SolarEdge
-
StorEdge Installation Guide MAN-01-00262-1.3
95