![SolarEdge StorEdge SE7600A-US1 Скачать руководство пользователя страница 41](http://html1.mh-extra.com/html/solaredge/storedge-se7600a-us1/storedge-se7600a-us1_installation-manual_1313757041.webp)
DIP Switch Setup in the Connection Unit
Verify that the DIP switches on the Connection Unit are set as described in the following table, according
to the components used in the system (see
):
l
In Connection Unit with two DIP switches:
Hardware configuration
Left DIP switch
(SW1) setup
Right DIP switch
(SW2) setup
Auto-transformer with connected over-temperature
sensor
ON ( up ) - default
OFF (down) - default
No auto-transformer, or auto-transformer with over-
temperature sensor not connected
ON ( up ) - default
ON ( up )
l
In Connection Unit with three DIP switches:
Hardware configuration
DIP switch 1
(leftmost) setup
DIP switch 2
(center) setup
DIP switch 3
(rightmost) setup
Auto-transformer with connected
over-temperature sensor
ON ( up ) - default
ON ( up ) - default
OFF (down) - default
No auto-transformer, or auto-
transformer with over-temperature
sensor not connected
ON ( up ) - default
ON ( up ) - default
ON ( up )
Figure 24: Connection Unit DIP switches
Chapter 6: StorEdge Inverter Connections
SolarEdge
-
StorEdge Installation Guide MAN-01-00262-1.3
39
Содержание StorEdge SE7600A-US1
Страница 1: ...SolarEdge StorEdge Solution with Backup Installation Guide For North America Version 1 3 ...
Страница 116: ......