Setting Up Communication
SolarEdge Installation Guide – MAN-01-00002-1.6
71
►
To connect the Ethernet communication to the
SolarEdge Monitoring server:
1
Open the cover of the inverter, as described in the
Opening the Cover
section
on page 37.
2
Using the user buttons, choose the
5.1.1 LAN
option under the
Communication
Server
menu (
5.1
), as described in the
Configuring the
Inverter Using the LCD Panel and User Buttons
section on page 88.
3
Configure the
LAN
options under the
Communication
menu (DHCP [
5.3.2
]
and IP [
5.3.1
] configurations), as described in the
Configuring the Inverter
Using the LCD Panel and User Buttons
section on page 88.
4
Prepare to connect the Ethernet cable to the Ethernet connector on board in
the inverter, as follows:
•
Insert the Ethernet wire via one of the small cable glands on the bottom
of the inverter.
If required, remove the existing plug.
The inverter
glands come pre-sealed from the factory. Removing the sealing is needed
to insert the cable.
CAUTION:
If a gland is opened and not used, then make sure to reseal it.
Otherwise, it may affect the inverter’s functionality.
CAUTION:
The internal side of the gland includes an o-ring, which should be used
to ensure proper sealing.
•
Remove the cable’s external isolation using the crimping tool or cable
cutter and expose 8 wires. Standard cables have 8 wires (4 twisted pairs).
For Ethernet communication, 4 wires (2 twisted pairs) are used.
Figure 38: Preparing Connector Wiring