SECTION 3 - INSTALLATION
Page S3-11
6. The flexible pvc pipe end that connects to the PCS1 inlet and outlet should
be equipped with a
PVC UNION
that allows for a quick disconnect. This union
should be cemented onto the flex pvc outside of the attic environment.
There is
absolutely no need to do any pvc cementing within the attic itself.
CAUTION: PVC cementing should only be done in well ventilated areas!
7. The
pool water temperature sensor
should be located directly after the filter
for best water temperature sensing.
NOTE
:
This sensor should be insulated after its
installation to prevent weather conditions from unduly influencing the sensed
temperature [of the pool] causing a false start or stop of the solar collection process.
8. The
check valve
prevents water from entering the PCS1 via its outlet.
9. Any chemical dispenser is located downstream from the PCS1 and must
not distribute chlorine or other chemicals directly into the PCS1.
10. The
skimmer suction line
may contain other valves to further split the
suction into additional paths. A typical example is the Òvacuum lineÓ which is
usually connected to the skimmer suction line using its own on/off gate valve.
11. Plumbing for a
pool vac
is left up to the installer. Such plumbing should
not defeat the purpose of flowreversal, if used, by sucking 90% of the water through
the vac. In such a case, pool heating would be heavily dependent upon the pool
vacÕs location. The pool vac could simply take water one foot from the main drain
and the system would return it out of the main drain in flowreversal causing a
ÒvortexÓ of water current and resulting in a false temperature condition, premature
shutdown of the solar collection process or erratic operation of the system.
12. An exploded view of the
flowreversal valve
, along with a more detailed
description of its operation is contained in the special report ÒHow To Create An
Energy Efficient PoolÓ which is available directly from SolarAttic, Inc.
13. The
proportioner valve
is used in conjunction with the flowreversalª
valve and is usually set once for the proper skimmer line suction. A proportioner
Содержание PCS1
Страница 7: ...SECTION 1 SYSTEM ARRIVAL Page S1 1 SECTION ONE SYSTEM ARRIVAL...
Страница 22: ...SECTION 2 HEATING DATA Page S2 1 SECTION TWO HEATING DATA...
Страница 28: ...BTUS Vs GPM BTUS Vs T SECTION 2 HEATING DATA Page S2 7...
Страница 34: ...SECTION 3 INSTALLATION Page S3 1 SECTION THREE INSTALLATION...
Страница 65: ...Attic Installation Photos SECTION 3 INSTALLATION Page S3 31...
Страница 66: ...Attic Installation Photos SECTION 3 INSTALLATION Page S3 32...
Страница 79: ...SECTION 3 INSTALLATION Page S3 45 STEP THREE AUTOMATING The PCS1 With Compool s LX220 Solar Controller...
Страница 88: ...SECTION 4 SERVICE Page S4 1 SECTION FOUR SERVICE...
Страница 99: ...Common Questions Page 1 of 10 COMMON QUESTIONS...
Страница 109: ...Dictionary of Terms Page 1 of 4 DICTIONARY OF TERMS...
Страница 113: ...Site Survey Page 1 of 4 SITE SURVEY...
Страница 116: ...Site Survey Page 4 of 4 Sketch Form...