Figure 3: Simplified heating diagram of configuration A. The yellow letters refer to explanatory notes of the function blocks, the blue
letters refer to explanatory notes of the temperature sensors. The outdoor unit of the heat pump is connected to the exchanger in the
storage tank by means of the refrigerant distribution in the direct condensation mode. The temperature of hot service water is
controlled automatically by a thermostatic mixing valve and it does not have to be controlled by the controller in any way. A
thermostatic valve for heat offtake for the radiators is not essential, nevertheless it enables a small continuous heat offtake from the
top part of the tank into the heating system. We always place the outside temperature sensor out of the flow of air cooled by the
outdoor unit.
Blocks:
A – PAST® storage tank
B – outdoor unit of the heat pump
C – solid fuel boiler
D – circulation pump of the solid fuel boiler
E – cold water input
F – hot service water output
G – thermostatic mixing valve
H – circulation pump of the heating circuit
I – radiators
J – circulation pump of the pool heating circuit
K – pool heat exchanger
L – circulation pump of the pool water
M – pool
N – expansion tank
Temperature sensors:
1 – solid fuel boiler – heating water input
2 – solid fuel boiler – heating water output
3 – storage tank – bottom of the tank
4 – storage tank – middle of the tank
5 – storage tank – top of the tank
6 – pool heat exchanger – pool water input
7 – outside temperature sensor