background image

2

 

Publisher
Solare Datensysteme GmbH
Fuhrmannstr. 9
72351 Geislingen-Binsdorf
Germany

International support
Tel.: +49 (0)7428/4089-300

e-mail: [email protected]

Italy
Technical support: +39 0471 631032
e-mail: [email protected]

France
Technical support: +33 97 7909708
e-mail: [email protected]

Switzerland
Technical support: +41 565 355346

e-mail: [email protected]

United States
Technical support: +1 203 702 7189
e-mail: [email protected]

Содержание Smart Relais Station 1x16A

Страница 1: ...1 Instructions Solar Log Smart Relais Station EN...

Страница 2: ...info solar log com Italy Technical support 39 0471 631032 e mail italy support solar log com France Technical support 33 97 7909708 e mail france support solar log com Switzerland Technical support 4...

Страница 3: ...nfiguration 9 3 1 Network design 9 3 2 Configuration IP Address of Solar Log Smart Relay Station 10 3 3 TCP IP configuration by DHCP 15 4 Operating 16 4 1 Operating the device directly 16 5 Firmware U...

Страница 4: ...Voltage and Temperature with optional sensor is shown in section Diagnostics Smart Energy Status current Legible LED display visualizes Total Current IP Address Sensor Values and Error Messages All ci...

Страница 5: ...ere excessive moisture or heat is present Because of safety and approval issues it is not allowed to modify the device without our permission Please note the safety advises and manuals of connected de...

Страница 6: ...tion 3 x 16A 3 relay outputs 4 L1 L3 indicator LED display 5 LED display for load or sensor display 6 3 indicator LEDs for relay outputs 7 Status LED 8 Button for OK Select or bootloader mode 9 Networ...

Страница 7: ...lay inputs with the corresponding phase Attach a switch if any to the stop input Connect the sensor if any to the device 2 2 Block Diagram L1 L1 N N LAN Sensor RS232 N A V Power supply AC or DC 12 24...

Страница 8: ...31 32 33 34 35 Block diagram for the Solar Log Smart Relais Station 3 x 16A 2 3 Status LED The Status LED shows different states of the device Red Device is not connected to the Ethernet Orange Device...

Страница 9: ...9 Configuration 3 Configuration 3 1 Network design The Solar Log Smart Relay Station must be in the same local area network as the Solar Log View of network topology...

Страница 10: ...2312 1 html Note In the manual you will find the screenshots of GBL_Conf 2 7 7 The latest GBL_Conf is 2 7 11 and has additionally the port HTTPS in the configuration See also GUDE Expert Net Control 2...

Страница 11: ...menu item Program Device using the Save Config function The network settings of the Solar Log Smart Relay Station have been adjusted Die Netzwerkeisntellungen der Solar Log Smart Relais Station wurde...

Страница 12: ...So lar Log Smart Relay Station is displayed Start screen of the Solar Log Smart Relay Station The IP configuration of the Solar Log Smart Relay Station has been successfully concluded Go to the web m...

Страница 13: ...ce Ethernet Number of devices 1 in the example Confirm the settings with OK Then start the device detection from the Configuration Devices Detection menu To enter the IP assigned above go to the Confi...

Страница 14: ...step is configuring the Smart Energy Logics Refer to the Solar Log Smart Energy Manual for more information It is available from our website https www solar log com manuals manuals en_GB SolarLog_ Ma...

Страница 15: ...se the software GBL_Conf exe or use the configuration via the web interface To check the network settings with GBL_Conf exe start the program and choose All Devices in the Search menu From the list se...

Страница 16: ...indicates that the output is off green shows that the output is on On the device are the buttons select and ok If you press select the LED will blink for the first output ie the output is selected Pr...

Страница 17: ...is not displayed correctly anymore this may be related to the interaction of Javascript with an outdated browser cache Not always helps a Ctrl F5 it is recommended that you manually delete the cache...

Страница 18: ...connect the power supply without operating a button By Software Start GBL_Conf exe Do a network search with the Search menu action In menu Program Device activate the item Enter Firmware 5 1 3 Factor...

Страница 19: ...x screw terminal with 1 x stop input 2 x screw terminal for neutral wire 1 x Mini DIN socket for external sensor Network connectivity 10 100 MBit s 10baseT Ethernet Protocols TCP IP HTTP DHCP ICMP SNM...

Страница 20: ...he following sensors are currently available Temperature Sensor 7001 Cable length 2m Connector Mini DIN Measurement range 20 C to 80 C at 2 C maximum and 1 C typical Humidity Temperature Sensor 7002 C...

Страница 21: ...liability for any errors or omis sions in such information Non compliance resulting in contradiction of the above mentioned specifications shall result in obligation to provide compensation for damag...

Отзывы: