The 208 / 240V version of the heater is fitted with 3 × supply cords measuring 79 inches (200 cm) 
for hard wiring.

 

 

WARNING: 

Wiring  procedures  and  connections  should  be  in  accordance  with  the  National    

Electric Code (NEC) and local codes.

 

 

WARNING: 

If  the  supply  cord(s)  becomes  damaged,  it  must  be  immediately  replaced  by  a     

qualified person in  order to avoid a hazard.

 

 

CAUTION: 

Disconnect  electric  power  supply  before  working  on  circuit  wiring  to  prevent  electric 

shock.

 

 

CAUTION: 

Please  observe  the  minimum  safe  distance  between  the  heater  body  and  any          

inflammable surfaces.

 

 

CAUTION: 

When the electrical connection is outside weatherproof sockets must be used having 

ground fault protection (GFCI or GFI).

 

NOTE: CONSULT A QUALIFIED ELECTRICIAN, IF IN DOUBT.

 

!

 

C O N F I G U R AT I O N S

 

 

The  Alpha  H3  heater  is  a  triple  emitter 

-

  it  contains  three  emitters.  It  can  be  installed  as  a 

single  unit  or  joined  to  another  single  unit.  Joining  bars  are  available  that  connect  the      
heaters together to increase the size and output of the installation. The maximum number of 
units that can be joined together is two. Please read the section ‘joining heaters together’ for 
information on how this should be done.

 

 

The Alpha H3 heater should only be wall mounted in a 
horizontal  manner  or  hung  from  a  ceiling  from  chains 
(not supplied).

 

 

 

When  wall  mounting  the  Alpha  H3  heater,  do  not     
position the heater at an angle more than 50° and less 
than 30° as shown in Fig. A.

 

 

 

When  ceiling  hanging  the  Alpha  H3  heater,  ensure 
the  minimum  distance  from  the  ceiling  is  adhered  to 
as shown in Fig. B.

 

Continued on next page...

 

M O U N T I N G  

-

  1  x   T R I P L E   ( 3   x   E M I T T E R S )   U N I T

 

C A U T I O N

 

Switch off/unplug the heater from the mains supply 
when mounting or adjusting the heater position.

 

6

 

Fig. A

 

S

E

E

 T

A

B

L

E

 1

 F

O

R

 

M

IN

IM

U

M

 H

E

IG

H

T

 

GROUND LEVEL 

Содержание Alpha H3 SALPHA3-6000

Страница 1: ...STRUCTIONS FOR FUTURE REFERENCE 247748 EN C COLOR CODE Reference Manual Solaira Alpha H3 Triple Emitter Candel Range CANADA USA MODELS SALPHAH3 30240LL C 208V 2250W 240V 3000W SALPHAH3 45240LL C 208V...

Страница 2: ...ever the heater is left operating and unattended 5 Do not operate any heater with a damaged cord or after the heater malfunctions has been dropped or damaged in any manner Return heater to authorized...

Страница 3: ...reas where gasoline paint or flammable liquids are used or stored 11 Do not cover or otherwise obstruct the heater IMPORTANT INSTRUCTIONS SAVE THESE INSTRUCTIONS GROUNDING INSTRUCTIONS For 240 or 208...

Страница 4: ...um height from the floor as specified below in the specification Table 1 3 Ensure that the heater has been securely fastened in its final mounting position 4 WARNING This appliance must be grounded an...

Страница 5: ...6 25 0 32 5 37 5 43 3 50 0 Min Mounting Height From Floor 98 in 250 cm 98 in 108 in 250 cm 274 cm 132 in 158 in 335 cm 401 cm 158 in 177 in 401 cm 450 cm Min Distance From Ceiling 19 in 50 cm Min Dis...

Страница 6: ...eater is a triple emitter it contains three emitters It can be installed as a single unit or joined to another single unit Joining bars are available that connect the heaters together to increase the...

Страница 7: ...selected to substantially support the weight of the installation If in doubt contact a professional for advice When hanging from a ceiling two equal length and gauge chains are required and should be...

Страница 8: ...heaters are joined they should only be hung from a ceiling on chains do not wall mount Always allow the heater to cool before attempting to reposition move Never attempt to move the heater while it is...

Страница 9: ...e replaced 2 Remove the screws from the terminal box at the back of the emitter to be replaced and lift off the lid see Fig F Fig F Fig G MAINTENANCE CAUTION REPLACING AN EMITTER CAUTION Unplug Switch...

Страница 10: ...th sides of the grille by undoing the centre screws and then remove the grille by pulling it out from the centre and prizing the prongs away from their locating holes at one end of the grille Fig L an...

Страница 11: ...f the side slot Fig Q and the lamp emitter can be lifted up completely The wire can then be gently pulled forward so that it also comes out from behind the reflector 10 The emitter can now be removed...

Страница 12: ...rille insert the 2 prongs into the holes in the grille holder Fig U and gently flex the grille to insert the 2 opposite prongs into the opposite grille holder holes as shown in Fig V Fig S Fig T Fig U...

Страница 13: ...13 WALL MOUNTED CONFIGURATION AT A GLANCE CHAIN HANGING CONFIGURATIONS AT A GLANCE 1 Alpha H3 Unit 2 Alpha H3 Units 1 Alpha H2 Unit...

Страница 14: ...make changes without notice 2020 INFORESIGHT CONSUMER PRODUCTS INC Ref No 042226 L1 Issue No 4 247748 IMPORTANT SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE Solaira Alpha H3 CANADA USA MODELS Solaira...

Отзывы: