I N S TA L L AT I O N
The 208 / 240V version of the heater is fitted with 3 × supply cords measuring 79 inches (200 cm)
for hard wiring.
WARNING:
Wiring procedures and connections should be in accordance with the National
Electric Code (NEC) and local codes.
WARNING:
If the supply cord(s) becomes damaged, it must be immediately replaced by a
qualified person in order to avoid a hazard.
CAUTION:
Disconnect electric power supply before working on circuit wiring to prevent electric
shock.
CAUTION:
Please observe the minimum safe distance between the heater body and any
inflammable surfaces.
CAUTION:
When the electrical connection is outside weatherproof sockets must be used having
ground fault protection (GFCI or GFI).
NOTE: CONSULT A QUALIFIED ELECTRICIAN, IF IN DOUBT.
!
C O N F I G U R AT I O N S
The Alpha H3 heater is a triple emitter
-
it contains three emitters. It can be installed as a
single unit or joined to another single unit. Joining bars are available that connect the
heaters together to increase the size and output of the installation. The maximum number of
units that can be joined together is two. Please read the section ‘joining heaters together’ for
information on how this should be done.
The Alpha H3 heater should only be wall mounted in a
horizontal manner or hung from a ceiling from chains
(not supplied).
When wall mounting the Alpha H3 heater, do not
position the heater at an angle more than 50° and less
than 30° as shown in Fig. A.
When ceiling hanging the Alpha H3 heater, ensure
the minimum distance from the ceiling is adhered to
as shown in Fig. B.
Continued on next page...
M O U N T I N G
-
1 x T R I P L E ( 3 x E M I T T E R S ) U N I T
C A U T I O N
Switch off/unplug the heater from the mains supply