41
ANNUAL PERFORMANCE CALCULATIONS FOR EUROPE
SYSTEM WIND AND SNOW LOAD PRESSURE
Under the requirements of EN 12795-1 (European Standard) the type of collector used in these systems has been tested
(ITW 11COL1015) to 2000 Pa, the maximum pressure (positive and negative) limit of the test equipment. This value has
been used to determine the maximum permissible limits of wind load (v
m
) as 56.6 m/s (203.6 km/h) and snow load (s
k
) as 2
kN/m
2
.
Systems or collector only installations using these collectors are only to be installed where the maximum values of s
k
(snow load) and v
m
(mean wind velocity) for the specific geographical area and installation circumstances do not exceed
the European permissible limit of wind and snow load. Values of v
m
and s
k
for your area can be obtained by consulting the
local dealer, a qualified structural engineer or relevant authorities.
These collectors and systems are routinely used in Australian Cyclonic regions.
J SYSTEMS
Annual performance calculations of Solahart thermosiphon J systems with the J collector according to EN12976
SolarKeyMark Systems ITW Test Report 10SYS82-1 for the 151J (150 tank, 1 collector), 181J (180 tank, 1 collector),
302J (300 tank, 2 collectors) and 303J (300 tank, 3 collectors) systems.
Qd = energy demand
QL = solar energy (load)
f-sol = solar fraction
Model
151J
151J
151J
151J
Demand
80 litres / day
110 litres / day
140 litres / day
200 litres / day
Location
Qd
MJ/a
QL
MJ/a
f-sol
%
Qd
MJ/a
QL
MJ/a
f-sol
%
Qd
MJ/a
QL
MJ/a
f-sol
%
Qd
MJ/a
QL
MJ/a
f-sol
%
Stockholm
59.6°N
4441
2101
47.3
6107
2644
43.3
7772
3047
39.2
11103
3375
30.4
Wurzburg
49.5°N
4257
2278
53.5
5854
2898
49.5
7450
3382
45.4
10643
3853
36.2
Davos
46.8°N
4820
3292
68.3
6628
4136
62.4
8435
4724
56.0
12050
5182
43.0
Athens
38.0°N
3305
2776
84.0
4545
3622
79.7
5784
4327
74.8
8263
5255
63.6
Model
181J
181J
181J
181J
Demand
80 litres / day
110 litres / day
140 litres / day
200 litres / day
Location
Qd
MJ/a
QL
MJ/a
f-sol
%
Qd
MJ/a
QL
MJ/a
f-sol
%
Qd
MJ/a
QL
MJ/a
f-sol
%
Qd
MJ/a
QL
MJ/a
f-sol
%
Stockholm
59.6°N
4441
2096
47.2
6107
2614
42.8
7772
3023
38.9
11103
3486
31.4
Wurzburg
49.5°N
4257
2273
53.4
5854
2868
49.0
7450
3353
45.0
10643
3959
37.2
Davos
46.8°N
4820
3268
67.8
6628
4049
61.1
8435
4648
55.1
12050
5314
44.1
Athens
38.0°N
3305
2763
83.6
4545
3581
78.8
5784
4292
74.2
8263
5354
64.8
Model
302J
302J
302J
302J
Demand
200 litres / day
250 litres / day
300 litres / day
400 litres / day
Location
Qd
MJ/a
QL
MJ/a
f-sol
%
Qd
MJ/a
QL
MJ/a
f-sol
%
Qd
MJ/a
QL
MJ/a
f-sol
%
Qd
MJ/a
QL
MJ/a
f-sol
%
Stockholm
59.6°N 11103
5030
45.3
13879
5676
40.9
16655
6096
36.6
22206
6373
28.7
Wurzburg
49.5°N 10643
5481
51.5
13304
6279
47.2
15965
6865
43.0
21286
7280
34.2
Davos
46.8°N 12050
7833
65.0
15063
8751
58.1
18075
9345
51.7
24100
9736
40.4
Athens
38.0°N
8263
6726
81.4
10329
7871
76.2
12395
8825
71.2
16526 10031
60.7
Model
303J
303J
303J
303J
Demand
200 litres / day
250 litres / day
300 litres / day
400 litres / day
Location
Qd
MJ/a
QL
MJ/a
f-sol
%
Qd
MJ/a
QL
MJ/a
f-sol
%
Qd
MJ/a
QL
MJ/a
f-sol
%
Qd
MJ/a
QL
MJ/a
f-sol
%
Stockholm
59.6°N 11103
5507
49.6
13879
6537
47.1
16655
7361
44.2
22206
8261
37.2
Wurzburg
49.5°N 10643
5886
55.3
13304
7051
53.0
15965
8046
50.4
21286
9259
43.5
Davos
46.8°N 12050
8724
72.4
15063 10333
68.6
18075 11622
64.3
24100 12869
53.4
Athens
38.0°N
8263
7181
86.9
10329
8697
84.2
12395 10040
81.0
16526 11998
72.6
Note: The over temperature protection tests have been carried out according to EN12976 with an irradiation higher than
20 MJ/m
2
/day. An over temperature protection device should be installed in the situation that irradiation this exposure
levels could be exceeded.
Содержание 151J
Страница 44: ...44 INSTALLATION DIAGRAMS MODELS 151J 181J 181LCSC 181BTC 151J 181J 181LCSC 181BTC J collector illustrated ...
Страница 45: ...45 INSTALLATION DIAGRAMS MODELS 151L 181L 151L 181L ...
Страница 46: ...46 INSTALLATION DIAGRAMS MODELS 302J 302LCSC 302BTC 303J 302J 302LCSC 302BTC 303J J collectors illustrated ...
Страница 47: ...47 INSTALLATION DIAGRAMS MODELS 302L 303L 302L 303L ...
Страница 51: ...CONNECTION DETAILS 51 With Pitch Tiled Roof Mounting ...
Страница 58: ...58 This page is intentionally blank ...
Страница 59: ...59 This page is intentionally blank ...