SAFETY, WARNINGS, INSTALLATION NOTES
8
Installation Notes
This water heater must be installed:
•
by a qualified person,
•
in accordance with the installation instructions,
•
in Australia in compliance with the Plumbing Code of Australia (PCA) and Plumbing Standard AS/NZS 3500.4, and
in other countries in compliance with their national plumbing Standards,
▪
This water heater is designed for outdoor installation.
▪
This water heater is intended to be permanently connected to the water mains and not connected by a hose-set. A
braided flexible hose or semi-flexible connector may be used for connection to the water heater, where permitted
by AS/NZS 3500.4.
•
in Australia and New Zealand in compliance with the Australian / New Zealand Wiring Rules AS/NZS 3000, and in
other countries in compliance with their national electrical Standards,
▪
Isolation switches must be installed in the electrical circuit to the water heater in accordance with the Wiring
Rules, so the water heater can be switched off.
▪
The power supply wires are to be directly connected to the terminal block and earth tab connection, with no
excess wire loops inside the front cover. The temperature rating of the power supply wires insulation must suit
this application, or the wiring protected by insulating sleeving with an appropriate temperature rating if it can
make contact with the internal storage cylinder. The temperature of the internal storage cylinder can reach 95°C
during its operation.
•
in compliance with all local codes and regulatory authority requirements,
•
in New Zealand also conforming to Clauses G12 and H1 of the New Zealand Building Code.
Installation and commissioning requirements and details for the installing plumber and licensed electrical worker are
contained on pages 20 to 52.
Mains pressure water supply
The water heater is designed to operate at mains pressure by connecting directly to the mains water supply.
The water heater is supplied with a temperature pressure relief valve with a pressure rating of 1000 kPa and an expansion
control valve with a pressure rating of 850 kPa.
The maximum mains water supply pressure for the water heater is 680 kPa when an expansion control valve is installed. If
the mains supply pressure in your area exceeds this value, a pressure limiting valve must be installed.
The supply pressure should be greater than 350 kPa for true mains pressure operation to be achieved.
Содержание 151J
Страница 44: ...44 INSTALLATION DIAGRAMS MODELS 151J 181J 181LCSC 181BTC 151J 181J 181LCSC 181BTC J collector illustrated ...
Страница 45: ...45 INSTALLATION DIAGRAMS MODELS 151L 181L 151L 181L ...
Страница 46: ...46 INSTALLATION DIAGRAMS MODELS 302J 302LCSC 302BTC 303J 302J 302LCSC 302BTC 303J J collectors illustrated ...
Страница 47: ...47 INSTALLATION DIAGRAMS MODELS 302L 303L 302L 303L ...
Страница 51: ...CONNECTION DETAILS 51 With Pitch Tiled Roof Mounting ...
Страница 58: ...58 This page is intentionally blank ...
Страница 59: ...59 This page is intentionally blank ...