172
The menu window displays the input with the new enabled condition:
Rising from "Low" to "High" (LH) or falling from "High" to "Low" (HL) and with the function
description.
Repeat the procedure for all other inputs to be assigned. Once you have all desired inputs assigned,
enable your entries with the F1 Enable key.
The F5 Cancel key closes the entry without saving changes.
See Section 7.11.3 Inputs for more details.
The display switches to weighing mode. The state for the input levels is displayed in the
information field; assigned inputs are highlighted dark, and highlighted light when inverted.
A totaling transaction or the retrieval of the organization data memory interrupts the display of the
inputs in the information field until the scale is again relieved.
Delete inputs
Press the F2 Inputs key in the Dynamic Switching Function level.
A list of the 4 inputs is generated with the enabled switching points.
All conditions can now be deleted with the F2 Delete key or the key.
The deletion is effective immediately and the scale goes back to weighing mode.
Fixed dynamic switching values (Switching Fix)
Up to 999 specific weights can be stored in a power failure-proof memory.
Each memory location has the following entries:
•
a three-digit sequential number
•
a name (alpha-numeric, max. 18 characters)
•
a part number (alpha-numeric, max. 18 characters)
•
Switching point S1 (switching condition, timer, polarity, lockout, possibly weight type and
value)
•
Switching point S2 (switching condition, timer, polarity, lockout, possibly weight type and
value)
•
Switching point S3 (switching condition, timer, polarity, lockout, possibly weight type and
value)
•
Switching point S4 (switching condition, timer, polarity, lockout, possibly weight type and
value)
•
Switching point S5 (switching condition, timer, polarity, lockout, possibly weight type and
value)
•
Switching point S6 (switching condition, timer, polarity, lockout, possibly weight type and
value)
•
Input E1 (function, signal flank)
•
Input E2 (function, signal flank)
•
Input E3 (function, signal flank)
•
Input E4 (function, signal flank)