129
Display sub-totals
While processing a recipe, you can display a total list of the fully processed containers. Press the
Info key followed by the F3 Total key.
The container, component unit count, gross total, tare total, net total, and unit count total are
displayed. Once the recipe was ended with the Total key, the list can no longer be retrieved.
6.10.6 Component control
The Component Control function can be used to weigh individual components into a container with
tolerance control.
Example: You wish to restrict the weight and to save a component only within a specified tolerance
range.
Press the F1 Comp Contr. key in the Recipe Function level 1. Use the number keypad to enter the
desired target value; confirm with the
F6 Save key. Use the number keypad to enter the acceptable tolerance in the weight unit of
measure; confirm with the F6 Save key.
Press the key to switch between weight unit of measure and percent.
If you wish to specify the plus and minus tolerances separately, you will need to enable Separate
+/- Tolerance in Setup Mode / Program Settings / Recipes. The display switches the relevant
Controlling display depending on the settings for the information field or the secondary display; the
special characters must be enabled. The appropriate special character is displayed to match the
current status of the scale to target value.
Control state
Indicator light color
Special character
Below tolerance limit
yellow
In tolerance
green
Exact target value reached
green
Above tolerance limit
red